4.2 Power Specification
Items
Specification
Power
AC110 ~ 240V, 60Hz
4.3 Environment Specification
4.3.1 This system operates in operating temperature between -40
°
C ~ +55
°
C without problem.
4.3.2 After testing the temperature/humidity test, there is no condensation inside of the system. 4.3.3 In
terms of not operating system, there is not condensation and function degradation due to
difference of temperature.
4.3.4 When testing prescribed vibration, there is no system and mechanical damage.
4.3.5 When testing prescribed rainfall, there is no water penetration.
4.3.6 Without external fan, it maintains proper temperature in enclosure.
4.3.7 Complied with Telcordia GR63-CORE(Dust).
4.3.8 This system is designed with compatible component for FCC & UL Certificate.
4.3.9 Major environment test condition is same as following table.
Items
Condition of application
Requirements
Storage Environment
Condition
• Temperature: -40 ~ +85
℃
• Humidity: 5 ~ 95%
No change of system function
Operation Environment
• Temperature: -40 ~ +55
℃
• Humidity: 5 ~ 100%
No change of system function
Vibration
• Vibration Range: 10 ~
150Hz
• 0.1 Octaves/min
• Earthquake test : Zone 4
No change of system function
No change inside/outside of enclosure
Altitude/Barometer
• 10000.ft AMSL.(Estimated
3,000M)
No change of system function
Waterproof
• NEMA Specification 4
No penetration of water inside
Anti-Dust
No change internal/external enclosure