www.frsky-rc.com
Latitude:
Latitude:
Latitude:
Latitude:
ddmm.mmmm N/S
Installation:
Installation:
Installation:
Installation:
Use double-sided tape to install the GPS on any appropriate surface of the airframe.
Note:
Note:
Note:
Note: Up
Up
Up
Up right
right
right
right position
position
position
position is
is
is
is recommended.
recommended.
recommended.
recommended.
2.3
2.3
2.3
2.3 Variometer
Variometer
Variometer
Variometer Sensor
Sensor
Sensor
Sensor (FVAS-01)
(FVAS-01)
(FVAS-01)
(FVAS-01)
Measurement
Measurement
Measurement
Measurement Range
Range
Range
Range of
of
of
of Altitude:
Altitude:
Altitude:
Altitude:
0~9000m
Accuracy:
Accuracy:
Accuracy:
Accuracy:
1m
Installation:
Installation:
Installation:
Installation:
Use double-sided tape to install the variometer sensor on any appropriate surface of the airframe.
Note:
Note:
Note:
Note: Wind
Wind
Wind
Wind will
will
will
will affect
affect
affect
affect the
the
the
the altitude
altitude
altitude
altitude reading.
reading.
reading.
reading.
2.4
2.4
2.4
2.4 Lipo
Lipo
Lipo
Lipo Voltage
Voltage
Voltage
Voltage Sensor
Sensor
Sensor
Sensor (F
(F
(F
(FL
L
L
LVS-01)
VS-01)
VS-01)
VS-01)
FrSky lipo voltage sensor will be released quite soon, which can monitor voltage for each cell. Current FrSky voltage sensor
(FBVS-01) is suggested to be connected to telemetry receiver’s analog ports (A1 & A2).
2.5
2.5
2.5
2.5 Temperature
Temperature
Temperature
Temperature Sensor
Sensor
Sensor
Sensor (TEMS-01)
(TEMS-01)
(TEMS-01)
(TEMS-01)
Up to two temperature sensors can be used at the same time. They are commonly used to read temperatures of model
accessories, such as electric motor, ESC, glow and gas engine cylinder head, battery, muffler, voltage regulator, BEC,
tailpipe and ambient air.
Measurement
Measurement
Measurement
Measurement Range:
Range:
Range:
Range:
-20~250 degrees Celsius/ -4~482 degrees Fahrenheit
Accuracy:
Accuracy:
Accuracy:
Accuracy:
1 degree Celsius/ 1 degree Fahrenheit
Installation:
Installation:
Installation:
Installation:
Use zip ties to hold the temperature sensor tightly against the accessory that requires temperature reading.
2.6
2.6
2.6
2.6 RPM
RPM
RPM
RPM Sensor
Sensor
Sensor
Sensor (RPMS-01)
(RPMS-01)
(RPMS-01)
(RPMS-01)
RPM sensor reads RPM data by using an optical sensor.
Measurement
Measurement
Measurement
Measurement Range:
Range:
Range:
Range:
0~60000r/min
Installation:
Installation:
Installation:
Installation:
Point the RPM sensor straight up at any accessory that requires RPM reading.
Note:
Note:
Note:
Note: Indoor
Indoor
Indoor
Indoor alternating
alternating
alternating
alternating current
current
current
current lighting
lighting
lighting
lighting will
will
will
will affect
affect
affect
affect the
the
the
the RPM
RPM
RPM
RPM reading.
reading.
reading.
reading.
2.7
2.7
2.7
2.7 Triaxial
Triaxial
Triaxial
Triaxial Acceleration
Acceleration
Acceleration
Acceleration Sensor
Sensor
Sensor
Sensor (TAS-01)
(TAS-01)
(TAS-01)
(TAS-01)
Measurement
Measurement
Measurement
Measurement Range:
Range:
Range:
Range:
±8g (9.8m/s2)
Accuracy:
Accuracy:
Accuracy:
Accuracy:
0.016g
Installation:
Installation:
Installation:
Installation:
Use double-sided tape to install the triaxial acceleration sensor on any appropriate surface of the airframe.
X/Y/Z axis has been labeled on the sensor.