3.
OPERATION
3.1.
INITIAL START-UP
In plug-in models, allow at least one hour to pass in order to let the oil
levels to stabilize, as they would have been displaced during
transportation.
Connect the cabinet to the mains and the display will light up showing two
horizontal strips. These indicate that the control is conducting a self-test.
After approximately 5 seconds the temperature that has been read by the control
will appear on the display and the unit will actuate itself.
The temperature controls and defrost times that we recommend for each cabinet
are based on our experience and laboratory tests. Different air conditions could
require controls that are different from those recommended.
The control components may only be operated by the technician
responsible for the installation.
The functions available to users are shutdown, start-up of the unit from the circuit
board and the start-up of the lighting from its corresponding switches.
3.2.
PRODUCT LOADING AND PRESERVATION
Please, don’t load product before three hours since starting up the cabinet.
Anycase, always check the working temperature before loading products inside.
Loaded product should be at least at its range temperature or better. The
cabinet is not able to decrease product temperature; cabinet only is able
to preserve temperature.
Please note the following points when loading the cabinet:
‐
Do not exceed the maximum load limit;
‐
Do not obstruct the aspiration grid or air discharge conduits;
‐
Do not load products that have higher temperatures than the
cabinet’s operating temperature;
‐
Load the products into the cabinet in such a way that you can ensure
good stock rotation;
‐
Empty spaces should be left between products to ensure perfect air
circulation around them.
Gloves should be worn when loading products into the cabinet.