background image

INSTALLATION AND MAINTENANCE MANUAL 

 

TRANSLATION OF THE 
ORIGINAL DOCUMENT 

For additional copies visit: 

www.frost‐trol.com

 

WALEN SOLID 

LINES 

D008586

 Versión: 

-18- 

 

3.

 

OPERATION 

 

3.1.

 

INITIAL START-UP 

 

 

In plug-in models, allow at least one hour to pass in order to let the oil 
levels to stabilize, as they would have been displaced during 

transportation.   

 

Connect the cabinet to the mains and the display will light up showing two 
horizontal strips. These indicate that the control is conducting a self-test.  
 

After approximately 5 seconds the temperature that has been read by the control 
will appear on the display and the unit will actuate itself. 

 
The temperature controls and defrost times that we recommend for each cabinet 

are based on our experience and laboratory tests. Different air conditions could 
require controls that are different from those recommended. 

 
The control components may only be operated by the technician 
responsible for the installation. 

 
The functions available to users are shutdown, start-up of the unit from the circuit   

board  and  the  start-up  of  the  lighting  from  its  corresponding  switches. 
 

 

3.2.

 

PRODUCT LOADING AND PRESERVATION 

 
Please, don’t load product before three hours since starting up the cabinet. 
Anycase, always check the working temperature before loading products inside. 

 

 

Loaded product should be at least at its range temperature or better. The 

cabinet is not able to decrease product temperature; cabinet only is able 
to preserve temperature. 

 
Please note the following points when loading the cabinet: 

 

 

Do not exceed the maximum load limit;  

 

Do not obstruct the aspiration grid or air discharge conduits; 

 

Do not load products that have higher temperatures than the 
cabinet’s operating temperature; 

 

Load the products into the cabinet in such a way that you can ensure 
good stock rotation; 

 

Empty spaces should be left between products to ensure perfect air 
circulation around them.  

 

 

Gloves should be worn when loading products into the cabinet. 

 

Содержание WALEN

Страница 1: ...TRANSLATION OF THE ORIGINAL DOCUMENT For additional copies visit www frost trol com Versi n 1 D008586 INSTALLATION AND MAINTENANCE MANUAL WALEN SOLID LINES...

Страница 2: ...8 DAMAGE SUSTAINED IN TRANSIT 12 1 9 TECHNICAL ASSISTANCE 12 1 10 STORAGE 12 2 INTALLATION OF REFRIGERATED DISPLAY CABINET 13 2 1 CABINET LOCATION 13 2 2 UPACKING 13 2 3 LEVELLING 14 2 4 INSTALLATING...

Страница 3: ...E ORIGINAL DOCUMENT For additional copies visit www frost trol com WALEN SOLID LINES D008586 Versi n 1 3 6 1 2 THE UNIT DOES NOT GET COLD ENOUGH 24 6 2 FINAL SHUTDOWN 26 6 3 DISMANTLING THE CABINET 26...

Страница 4: ......

Страница 5: ...t to break down It s mandatory to leave 8cm between the cabinet rear wall and the supermarket wall to ensure the airflow Keep clear of obstructions all ventilation openings of the cabinet enclosure Do...

Страница 6: ...servicing of the unit The power cords must be properly spread out safe from shocks and far from liquids water and heat sources and in perfect condition The use of adaptor plugs is forbidden If the pow...

Страница 7: ...on the external walls of the equipment as this could compromise cabinet performance In order to reduce flammability related risks this cabinet may only be installed by suitably qualified personnel Pro...

Страница 8: ...vity from these units and also so that the Marketing Director is able to gain the maximum commercial return possible Read this manual carefully and store it with the refrigeration unit Pay particular...

Страница 9: ...he presentation of meat products delicatessens and cheeses The cabinet has a wide range of optional accessories If you need details about its assemblage please contact with Frost trol S A The sections...

Страница 10: ...n order to access the EPREL database you can either scan the QR code from the energy label provided with the appliance or access the EPREL website and introduce the model identifier see Table 1 I QR C...

Страница 11: ...HOTTEST PRODUCT MINIMUM TEMPERATURE OF THE COLDEST PRODUCT C C C L1 15 18 15 18 L2 12 18 12 18 L3 12 15 12 15 Table 3 Temperature depending on class for freezing cabinets 1 6 OPERATING THE COOLING SYS...

Страница 12: ...stallation of the refrigerated display cabinet or cooling system please contact our Technical Department If you need to get in contact with Frost Trol with regard to a specific element please make sur...

Страница 13: ...densing units into the cabinet or onto its condensing unit The refrigerated display cabinet must not be installed in places where explosive gases are present Do not expose the equipment to atmospheric...

Страница 14: ...st possible heights whilst allowing the section to remain horizontal This will ensure that the bases on the end sections do not need to be excessively extended 2 4 INSTALLATING THE DRAINAGE SISTEM An...

Страница 15: ...ent points in the refrigeration cycle condenses into micro drops of H2O which then get deposited and accumulate in the solder joint cracks on the low pressure side When the H2O changes state into a so...

Страница 16: ...cap on the thermostatic expansion valve reheating screw and close its lid 2 8 ELECTRICAL CONNECTION The assembly installation and connection of these cabinets must be carried out by a certified techni...

Страница 17: ...ect condition The use of adaptor plugs is forbidden If the power cord is damaged it must be replaced by the manufacturer in order to avoid a hazard Technical cabinet data are showed in the nameplate s...

Страница 18: ...ay only be operated by the technician responsible for the installation The functions available to users are shutdown start up of the unit from the circuit board and the start up of the lighting from i...

Страница 19: ...should be closed as long as possible In this way excessive energy consumptions as well as frost buildup on the inner walls will be avoided An improper preservation temperature may turn the foodstuffs...

Страница 20: ...ANCE DOORS MONTHLY CLEANING GENERAL EVERY 2 OR 3 MONTHS Tabla 4 Cleaning routine Do not allow any water to spatter or be sprayed over the unit s electrical elements Should this happen make sure that t...

Страница 21: ...reach ambient temperature and no frost rests remain Don t use metallic or cutting objects to accelerate the process It may scratch or damage inner surfaces Clean inner parts with warm water and neutra...

Страница 22: ...leaner Mount and screw the front grille Finally plug de cabinet 4 4 SLIDING DOORS MAINTENANCE In order to ensure the proper and easy sliding operation you must apply every 30 days or whenever it prove...

Страница 23: ...nside the refrigerated cabinet on the characteristics plate Taking the customer s standing position as a reference You may request to Frost trol the spare parts cross section Tabla 5 Name plate Accord...

Страница 24: ...ctly loaded i e the products do not exceed the maximum load limit and the conservation temperature is suitable for the products Check that there is no air flow that will affect the operation of the un...

Страница 25: ...dmade drawing or photos could be appreciated Thermostat setting Defrost interval Defrost endurance time End defrost temperatura State of the fans on defrost cycle on off Evaporating pressure measured...

Страница 26: ...uired to deliver the product for disposal to the collection centre specified by the local authorities for recovery and recycling of professional WEEE In the case of trade in of the old product for a n...

Страница 27: ...s with the provisions of Directive 2002 96 EEC RoHS In all the homogeneous materials used for its production any content of lead mercury hexavalent chrome polybrominated biphenyl PBB and polybrominate...

Страница 28: ...fo frost trol com ESPA A PLANTA CABANES CV 159 Km 2 12180 Cabanes Castell n Spain Tel 34 964 342 740 Fax 34 964 215 148 info frost trol com M XICO Av Pirules 134 B esquina con Av Tejocotes Fraccionami...

Отзывы: