Waste Oil Caddy  |   

Frontline International Inc

.

PROBLEM

PROBABLE CAUSE

CORRECTIVE ACTION

Caddy motor will not run.

The caddy motor is not 

turned ON.

Turn the motor ON with the switch located on the back of the 

motor.

Caddy motor reset switch 

has tripped.

Press the motor reset switch on the back of the caddy motor.

The caddy power cord 

is not making proper 

connection.

Ensure the caddy power cord is completely plugged into the 

motor and the control panel receptacle .

The tank or control panel 

at the fill station has lost 

power.

Ensure the tank or fill station control panel are plugged in.
Ensure the outlet that the tank or fill station control panel is 

plugged into has not lost power.
If there is no power to the outlet make sure the circuit breaker 

has not tripped or that the outlet is not on a switch that has 

been turned off.

Caddy motor runs but no  

oil will pump.

Disconnect fittings are not 

properly connected.

Make sure the female disconnect fitting is properly connected 

to the male fitting.

Caddy hose may be 

plugged with grease.

Run the caddy hose under hot water to liquefy any grease that 

may be clogging the hose.

Caddy pump may be 

plugged with grease.

Remove the four screws on the front of the pump and clean the 

inlet and outlet port of the pump, and the rotor gear.

Make sure that nothing is blocking the inlet tube that goes 

down into the oil.
Assure that the oil being discarded is in liquid state.

Call 330-861-1100 if you have checked all of the above and the problem still has not been resolved.

 Troubleshooting

See the following table to troubleshoot problems

Содержание 10SS-NA

Страница 1: ...dy 20Gal 75 7 l 16SS NA W5 Transport Caddy with 5 12 7 cm Castors 16Gal 60 5 l 20SS NA W5 Transport Caddy with 5 12 7 cm Castors 20Gal 75 7 l DANGER Please read this operation and servicing manual tho...

Страница 2: ...transport or filter cooking oil for immediate on premise recycling and use A stakeholder focused organization our sustainability relies on initiatives that benefit associates customers and community f...

Страница 3: ...10079 3 4 x 12 Galvanized Nipple 10010007 3 4 x 1 2 Galvanized Reducing Hex Brushing 10030008 500White Kleenflow Hose 48 L 1 2 NPT Swivel one end 1 2 NPT Rigid one end 10020001 1 2 Quick Disconnect Co...

Страница 4: ...chicken drippings may be disposed if placed in the filter basket and mixed with hot oil 5 Note that the temperature should be at least 100F 38C but not higher than 375F 190C Never drain oil into the...

Страница 5: ...d back push the female fitting onto the male fitting on the tank or fill station 10 Gently pull on the caddy hose to ensure a proper connection has been made IMPORTANT The caddy pump could be damaged...

Страница 6: ...ddy is empty 15 Use gloves to disconnect the hose from the tank and place the female fitting onto the male fitting on top of the caddy IMPORTANT The hose will be HOT Use gloves 16 Push the black butto...

Страница 7: ...there is no power to the outlet make sure the circuit breaker has not tripped or that the outlet is not on a switch that has been turned off Caddy motor runs but no oil will pump Disconnect fittings a...

Страница 8: ...to pump solid or cold grease this will clog the pump Make sure oil is warm and liquid before pumping 3 Do not attempt to pump oil if green light on the control panel is not lit 4 Grill grease or chic...

Страница 9: ...ir or replacement of the defective part and any labor charges for the removal and installation of any non user part specified above Replacement parts do not have any labor coverage Any claim must be r...

Страница 10: ...8 Frontline International Inc Portador de aceite de desecho Frontline International Inc 187 Ascot Parkway Cuyahoga Falls Ohio 44223 Phone 330 861 1100 Fax 330 861 1105 www frontlineii com...

Отзывы: