Poor weld properties
Incorrect welding parameters
Check the settings
Poor ground earth connection
Ensure good contact to workpiece
Inadequate or no protective gas shield
Check the pressure regulator, gas hose, gas solenoid valve, torch gas con-
nection, etc.
Welding torch is leaking
Change the welding torch
Wrong contact tip, or contact tip is worn out
Replace the contact tip
Wrong wire alloy or wrong wire diameter
Check the wire electrode that has been inserted
Wrong wire alloy or wrong wire diameter
Check weldability of the base material
The shielding gas is not suitable for this wire alloy
Use the correct shielding gas
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
60
Содержание WF 15i
Страница 2: ......
Страница 16: ...16...
Страница 17: ...General 17...
Страница 18: ...18...
Страница 21: ...Controls connections and mechan ical components 21...
Страница 22: ...22...
Страница 29: ...OPT i WF Stand ard control panel 1 9 8 5 6 10 11 12 2 3 4 7 14 13 29 EN...
Страница 34: ...34...
Страница 35: ...Installation and commissioning 35...
Страница 36: ...36...
Страница 41: ...2 41 EN...
Страница 50: ...1 1 Contact pressure preferred values for U groove rollers Steel 4 5 CrNi 4 5 Tubular cored electrodes 2 3 50...
Страница 54: ...54...
Страница 55: ...Troubleshooting maintenance and disposal 55...
Страница 56: ...56...
Страница 63: ...Technical data 63...
Страница 64: ...64...
Страница 68: ...HP 70i HP PC Cable HD 70 Welding current at 10 min 40 C 104 F 60 ED 600 A 100 ED 500 A ED Duty cycle 68...
Страница 69: ...69 EN...
Страница 70: ...70...
Страница 71: ...71 EN...