Technical data
TTW 4500, TTW
5500
TTW 4500
TTW 5500
Voltage measurement (V-Peak)
141 V
141 V
Shielding gas
Argon EN 439
Cooling system
Liquid cooling
Coolant
Original Fronius coolant
Cooling power
800 W *)
1000 W *)
Max. coolant pressure
5.5 bar
79.74 psi.
5.5 bar
79.74 psi.
Min. coolant pressure
3.0 bar
43.5 psi.
3.0 bar
43.5 psi.
Minimum coolant flow rate
1.0 l/min
1.0 l/min
DC welding current at 10
min / 40° C (104° F)
100% duty cycle (D.C.)
60% D.C.
350 A
450 A
430 A
550 A
AC welding current at 10
min / 40° C (104° F)
100% D.C.
60% D.C.
250 A
320 A
300 A
400 A
*) Lowest cooling power according to standard IEC 60974-2
The product conforms to the requirements of standard IEC 60974-7
11
EN
Содержание TTW 5500
Страница 2: ......
Страница 8: ...2 1 3 15 mm 3 1 Push on as far as it will go 4 1 2 5 8...
Страница 12: ...12...
Страница 18: ...2 1 3 15 mm 3 1 Zamontowa do oporu 4 1 2 5 18...
Страница 22: ...22...
Страница 26: ...O TTW 4500 1 2 1 1 2 2 1 3 2 4 3 4 26...
Страница 28: ...2 1 3 15 mm 3 1 4 1 2 5 28...
Страница 29: ...O 29 ZH...
Страница 30: ...O 30...