Cause:
Primary overcurrent
Remedy:
Contact After-Sales Service
Power source has no function
Mains switch is on, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged
in
Remedy:
Check the mains supply lead, make sure that the mains plug is
plugged in
Cause:
Mains socket or mains plug faulty
Remedy:
Replace faulty components
Cause:
Mains fuse is faulty
Remedy:
Change the mains fuse
No welding current
mains switch is on, overtemperature indicator is lit up
Cause:
Overload; the duty cycle has been exceeded
Remedy:
Do not exceed the duty cycle
Cause:
Thermostatic cut-out system has tripped
Remedy:
Wait until the power source automatically switches back on after
the cooling phase has finished
Cause:
The fan in the power source is faulty
Remedy:
Replace the fan (After-Sales Service)
No welding current
mains switch is on and indicators are lit up
Cause:
Grounding (earthing) connection is incorrect
Remedy:
Check the earth (ground) connection and clamp for correct po-
larity
Cause:
There is a break in the current cable in the welding torch
Remedy:
Replace the welding torch
Nothing happens when torch trigger is pressed
mains switch is on and indicators are lit up
Cause:
The control plug is not plugged in
Remedy:
Insert the control plug
Cause:
Welding torch or welding torch control line defective
Remedy:
Replace the welding torch
No shielding gas
all other functions are OK
Cause:
The gas cylinder is empty
Содержание TransTig 1750 Puls
Страница 2: ...0 ...
Страница 4: ...2 ...
Страница 8: ...6 ...
Страница 22: ...20 ...
Страница 23: ...General information ...
Страница 24: ......
Страница 26: ...24 ...
Страница 27: ...Control elements and connections ...
Страница 28: ......
Страница 36: ...34 ...
Страница 37: ...Installation and commissioning ...
Страница 38: ......
Страница 44: ...42 ...
Страница 45: ...Welding ...
Страница 46: ......
Страница 50: ...48 I t I1 GPr IS tdown IE G L G H I1 I2 tup tE tS ...
Страница 62: ...60 The anti stick function can be activated and deactivated in the Setup menu level 2 sec tion ...
Страница 63: ...Setup settings ...
Страница 64: ......
Страница 77: ...Troubleshooting and maintenance ...
Страница 78: ......
Страница 83: ...Appendix ...
Страница 84: ......
Страница 86: ...84 Spare parts list ...