23
I
2
I
1
Duty-Cycle
0
I
t
T= 1/f
(Hz)
50%
50%
Fig. 23
Setting-example Duty-Cycle in scale position "50"
With the TR 50mc remote control pulsing unit two operational modes are possible:
-
Regulation of impulse current I
1
by TR 50mc remote control unit.
-
Adjustment of impulse current I
1
by means of the TR 52mc remote control pedal
unit.
(23)
Pulsing current dial I
1
(main current)
-
For continuous adjustment of the pulsing / main current
(24)
Pulse frequency dial f
(Hz)
-
For continuous adjustment of the pulse frequency, depen-ding on which
frequency range has been preselected by switch (27).
(25)
Background current dial I
2
-
The setting for the background current is made as a percentage of the value
set for the pulsing current I
1
(26)
Duty-Cycle dial %
-
Setting dial for pulse / interval relationship = this dial is for setting the relati-
onship, in percentage terms, between the pulsing current phase and the
background current phase.
Setting-examples
Duty cycle dial (26) is in scale position 10,
-
Short pulsing current phase of 10 %
-
Long background current phase of 90 %
-
Low degree of heat impact.
Duty Cycle dial (26) is in scale position 50,
(see Fig.23)
-
Pulsing current phase and background current phase are equally long (each 50
%)
l
Means medium degree of heat impact.
Duty cycle dial (26) is in scale position 90,
-
Long pulsing current phase of 90 %
-
Short background current phase of 10 %
-
High degree of heat impact.
TR 50mc remote
control pulsing
unit
(contiued)