![Fronius TransPocket 180 RC HW Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/fronius/transpocket-180-rc-hw/transpocket-180-rc-hw_operating-instructions-manual_2339428035.webp)
35
EN-US
E37
Cause:
Grid voltage exceeds admissible limits
Remedy:
Immediately pull out the mains plug and ensure that the power source is being
operated at the correct grid voltage
E36 E41 E45
Cause:
Grid voltage is outside of the tolerance or grid output is insufficient for the con-
nected device(s)
Remedy:
Ensure that the power source is being operated at the correct grid voltage; en-
sure the correct fuse is set;
E65 - E75
Cause:
Communication error with welding torch/remote control
Remedy:
Check TIG Multi Connector plug connection / turn device off and on again /
inform service team if this happens multiple times
No Function
Device cannot be switched on
Cause:
Defective power switch
Remedy:
Inform service team
No current for pre-heating the wire electrode
The power source is switched on
Cause:
Power cable connection has been interrupted
Remedy:
Properly connect power cable
Cause:
Poor or no ground earth connection
Remedy:
Establish a connection with the workpiece