Entering/exiting the Setup menu

Process parameters

Start/End

I-S

Starting current (135)

AlS

Start arc length correction (0)

t-S

Starting current time (off)

SL1

Slope 1 (1.0)

SL2

Slope 2 (1.0)

I-E

Final current (50)

AlE

End arc length correction (0.0)

t-E

Final current time (off)

SFI

SFI ignition (off)

SFI-HS

SFI HotStart (off)

W-r

Wire retract (0.0)

IgC

Ignition current (manual), (450)

W-r (man.) Wire retract (manual), (0.0)

Gas Setup

Gpr

Gas pre-flow (0.1)

GPo

Gas post-flow (0.5)

Process control

PSt

Penetration stabilizer (0.0)

AISt

Arc length stabilizer (0.0)

Components

C-C

Cooling unit operating mode (auto)

C-t

Filter time flow sensor (10)

Fdi

Feeder inching speed (10.0)

ito

Ignition timeout (off)

STICK

I-S

Starting current (150)

Hti

Starting current time (0.5)

Eln

Characteristic (I-constant)

Ast

Anti-stick (on)

Uco

Break voltage (90.0)

TIG

Uco

Break voltage (14.0)

CSS

Comfort-Stop sensitivity (0.8)

SynchroPulse

Syn-Puls

SynchroPulse (off)

vd

Wire speed (5.0)

dFd

Delta wire feed (2.0)

F

Frequency (3.0)

DC

Duty cycle (50)

Al-h

Arc correction high (0.0)

Al-l

Arc correction low (0.0)

Process Mix

vd

Wire speed (1.5)

AlC

Arc length correction (0.0)

PDc

Pulse/dynamic correction (0.0)

Hptc

Upper power time correction (0)

Lptc

Lower power time correction (0.0)

Lpc

Lower power correction (0.0)

R/L-check / alignment

Aligning welding circuit resistance 

welding circuit inductivity

Settings

Display

Einh.

Units

Norm

Standards

UIBS

Display brightness setting

F1/F2 Param.

User-defined parameters for F1 

and F2

Favorit

Favourite key

IP

System data

System

CLS

Housing lighting setup

FAC

Restore factory settings

Web-PW reset

Reset website password

Information:

IM-V. / SWV / IP

Operating mode setup: S4T / iJob
Language

cs, de, en, etc.

Activating/deactivating the key lock

Text display

Abbreviation

Full text

Favourite

The Favourite key can be assigned the Setup parameter or Setup 
folder that is currently selected.
Retrieve:

1x

Save:

Delete:

EasyJobs

The EasyJob keys allow up to 5 
operating points to be saved. Specif-
ically, the current welding-relevant 
settings are saved.

Retrieve:

1x

Save:

Delete:

F1 / F2 special function parameters

F1 and F2 can be assigned the currently selected setup parame-
ters.

Retrieve:

Save:

Delete:

Use the key for 
F2!

(Values/entries in brackets show the factory setting)