![Fronius RI FB PRO/i Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/fronius/ri-fb-pro-i/ri-fb-pro-i_operating-instructions-manual_2339326032.webp)
Address
Signal
Ac
tivit
y /
da
ta t
ype
Range
F
ac
tor
Process
image
relative
absolute
Standar
d
Econom
y
W
ORD
B
YTE
B
IT
BIT
6
12,
13
0-7
96-111
With the welding process
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Arclength correction
SINT16
-10.0 to
100.0
[m/min]
10
ü
ü
With the welding process
MIG/MAG standard manu-
al:
Welding voltage
UINT16
0.0 to
6553.5 [V]
10
With the Job mode:
Arclength correction
SINT16
-10.0 to
10.0
[Steps]
10
With the welding process
ConstantWire:
Hotwire current
UINT16
0.0 to
6553.5 [A]
10
7
14,
15
0-7
112-127
With the welding process
MIG/MAG pulse synergic,
MIG/MAG standard syner-
gic,
MIG/MAG PMC,
MIG/MAG LSC,
CMT:
Pulse-/dynamic correction
SINT16
-10.0 to
10.0
[Steps]
10
ü
ü
With the welding process
MIG/MAG standard manu-
al:
Dynamic
UINT16
0.0 to 10.0
[Steps]
10
8
16
0-7
128-135
Wire retract correction
UINT16
0.0 to 10.0
[Steps]
10
ü
17
0-7
136-143
9
18
0-7
144-151
Welding speed
UINT16
0.0 to
1000.0
[cm/min]
10
ü
19
0-7
152-159
10
20
0-7
160-167
Process controlled correc-
tion
See table
ü
21
0-7
168-175
11
22
0-7
176-183
—
ü
23
0-7
184-191
32