Do not remove cover!
Each Terminal: I
max
= 15 A
Inverter DC
Connection
The inverter is designed exclusively to
be connected and used with nongroun-
ded solar modules.
The solar modules cannot be grounded
at either the positive or negative pole.
IMPORTANT!
Check the polarity and voltage of the solar module strings.
If DC cables are laid over the shaft of
the DC main switch, or across the DC
main switch connection block, they
could be damaged when the inverter
swivels in, or the inverter could be pre-
vented from swiveling in.
IMPORTANT!
Do not lay the DC cable
over the DC main switch or across the
DC main switch connection block.
Multi MPP
Tracker inverter
– Fronius Primo
3.0–8.2
Multi MPP Tracker inverters have two independent DC inputs (MPP Tracker).
These inputs can be connected to a number of different modules.
Each MPP Tracker has 2 DC+ terminals. There are a total of four DC- terminals.
36
Содержание Primo 10.0-1 208-240
Страница 2: ......
Страница 13: ...Preparation 13...
Страница 14: ...14...
Страница 16: ...Opening the in verter 1 2 Installing the mounting brack et on a brick or concrete wall 1 2 3 16...
Страница 21: ...AC 21...
Страница 22: ...22...
Страница 31: ...DC 31...
Страница 32: ...32...
Страница 42: ...2 2 1 max 0 28 in 7 mm 8 Fit the padlock to the anti theft device 42...
Страница 50: ...50...
Страница 51: ...51 EN US...
Страница 52: ......