Fronius Primo 10.0-1 208-240 Скачать руководство пользователя страница 1

Installation

Instructions

Fronius Primo 208-240:
3.8-1 / 5.0-1 / 6.0-1
7.6-1 / 8.2-1
10.0-1 / 11.4-1
12.5-1 / 15.0-1

42,0426,0197,EA

017-10082022

EN-US

Installation instructions

Содержание Primo 10.0-1 208-240

Страница 1: ...Installation Instructions Fronius Primo 208 240 3 8 1 5 0 1 6 0 1 7 6 1 8 2 1 10 0 1 11 4 1 12 5 1 15 0 1 42 0426 0197 EA 017 10082022 EN US Installation instructions...

Страница 2: ......

Страница 3: ...he inverter on a mast 18 Notes on the Knockouts 19 Safety 19 General 19 Knocking or drilling out knockouts 19 AC 21 Suitable Grids 23 Suitable Grids 23 Connecting the inverter to the public grid AC si...

Страница 4: ...n the USB stick 44 Data Amount and Memory Capacity 45 Buffer Memory 46 Suitable USB Thumb Drives 46 USB Stick for Updating Inverter Software 47 Removing the USB Stick 47 Notes on Maintenance 48 Mainte...

Страница 5: ...and tested according to international safety require ments Due to its electrical and electronic components certain precautions must be taken when installing and operating the inverter In order to redu...

Страница 6: ...seen easily Set the inverter so that an error message is displayed if the fuse trips Fire prevention CAUTION Danger from faulty or incorrect installations They may result in damage to inverters and o...

Страница 7: ...ot to be in conformity with its intended purpose utilization for any other purpose or in any other manner alterations to the inverter that are not expressly recommended by Fronius installation of comp...

Страница 8: ...ot sus ceptible to hose water on any side and can also be operated in moist environments In order to keep inverter heating as low as possible do not expose the inverter to direct sunlight The inverter...

Страница 9: ...as where there is an increased risk of accidents from farm animals horses cattle sheep pigs etc Stables or adjoining areas Storage areas for hay straw chaff animal feed fertilizers etc The inverter is...

Страница 10: ...loping surface Do not install the inverter on a sloping surface with the connec tions upwards Do not install the inverter in a sloping position on a vertical wall or column Do not install the inverter...

Страница 11: ...waste air can reach a temperature of 70 C When installing the inverter in a switch cabinet or similar closed environment it is necessary to make sure that the hot air that develops will be dissipated...

Страница 12: ...ed environment it is necessary to make sure that the hot air that develops will be dissipated by forced air ventilation If you wish to install the inverter on the outer walls of a cattle shed it is im...

Страница 13: ...Preparation 13...

Страница 14: ...14...

Страница 15: ...oiled or wet The mounting bracket without integrated inverter does not correspond to the degree of protection according to the data sheet For this reason do not leave the mounting bracket exposed to e...

Страница 16: ...Opening the in verter 1 2 Installing the mounting brack et on a brick or concrete wall 1 2 3 16...

Страница 17: ...he mounting brack et to a timber wall 1 Do not warp or deform the mounting brack et When attaching the wall bracket to the wall or to a column make sure that the wall bracket is not warped or deformed...

Страница 18: ...ounting bracket must be secured in at least four places 1 Installing the in verter on a mast Example of a mast mounting kit For installation of the inverter on a mast or beam Fronius recommends using...

Страница 19: ...r General The wall bracket contains several knockouts of different sizes When knocked out the openings are used for feeding in the various cables 1 2 in for data communication cable DATCOM for Fronius...

Страница 20: ...drilling out using a step drill ensure that the DC discon nector and the AC DC connection block are not damaged When drilling out the knockouts at the back place the mount ing bracket on an even surf...

Страница 21: ...AC 21...

Страница 22: ...22...

Страница 23: ...eutral conductor 240 V 120 V WYE with neutral conductor 240 V 120 V split phase with neutral conductor 50 Hz 220 V Delta Corner Grounded 50 Hz without neutral conductor 50 HN 220 V Delta 127 V WYE 50...

Страница 24: ...220 V Delta Corner Grounded Setup 220 No neutral conductor 220 V Delta 127 V WYE Setup 220N Neutral conductor available 240 V Delta Corner Grounded Setup 240 CAL5 HI5 No neutral conductor 24...

Страница 25: ...grid WARNING Inadequately sized electrical components can cause serious injury and damage to property An electric shock can be fatal All electrical connections must be established in accordance with...

Страница 26: ...um cables Follow the instructions of the cable manufacturer especially the note about whether an annual check to ensure that the cables are firmly attached should be performed NOTE Form a min 4 in 100...

Страница 27: ...lu minum cables Reduced rated currents for aluminum cables The connection requirements listed below Always follow the instructions of the cable manufacturer when using aluminum cables Take into accoun...

Страница 28: ...last Measure the ground conductor GND longer for example and loop Example Fronius Primo 3 8 8 2 If AC cables are laid over the shaft of the DC main switch or across the DC main switch connection bloc...

Страница 29: ...ronius Primo 5 0 1 208 240 1 2 5000 W 63 A Fronius Primo 6 0 1 208 240 1 2 6000 W 63 A Fronius Primo 7 6 1 208 240 1 2 7600 W 63 A Fronius Primo 8 2 1 208 240 1 2 8200 W 63 A Fronius Primo 10 0 1 208...

Страница 30: ...riggered for the type A residual current circuit breaker in individual cases and depending on local conditions For this reason Fronius recommends that you use a residual current circuit breaker suitab...

Страница 31: ...DC 31...

Страница 32: ...32...

Страница 33: ...Inadequately sized electrical components can cause serious injury and damage to property An electric shock can be fatal All electrical connections must be established in accordance with the nation al...

Страница 34: ...r The inverter may be damaged Only connect a maximum of 20 A to each DC terminal Connect the DC and DC cables to the correct DC and DC terminals on the inverter Observe the maximum DC input voltage NO...

Страница 35: ...module grounding String Fuses Only valid for the device types with the Ecofuse option The use of string fuses provides additional fuse protection for solar modules The maximum short circuit current I...

Страница 36: ...module strings If DC cables are laid over the shaft of the DC main switch or across the DC main switch connection block they could be damaged when the inverter swivels in or the inverter could be pre...

Страница 37: ...odule fields to a line on a Multi MPP Tracker inverter If the strings are connected with a string collection box and only one col lective line is used for connection to the inverter connection DC 1 pi...

Страница 38: ...C lines are distributed evenly across both in puts Multi MPP Tracker Inverter Fronius Primo 10 0 15 0 Multi MPP Tracker inverters have 2 independent DC inputs MPP Tracker These inputs can be connected...

Страница 39: ...plied protective hose Knock out the appropriate opening Cleanly deburr the knocked out opening Fronius Primo 3 9 8 2 only Insert the supplied cable gland into the opening if both openings are knocked...

Страница 40: ...inverter in the wall bracket when the DC main switch is off Do not use excessive force to clip on the inverter and pivot it The fixing screws in the data communication area of the inverter are used t...

Страница 41: ...verter Push the fixing screw upwards from the other side e g using needle nose pli ers Undo the fixing screw Mounting the Anti Theft Device IMPORTANT Please refer to the instructions for attaching the...

Страница 42: ...2 2 1 max 0 28 in 7 mm 8 Fit the padlock to the anti theft device 42...

Страница 43: ...dates Notes on Soft ware Updates USB 3 5 4 4 1 2 2 1 Insert the USB stick in the inverter data communication area 2 Access the Setup menu 3 Select the USB menu item 4 Select Update Software 5 Install...

Страница 44: ...er that is irrelevant to the custom er The file must not be deleted individually Only delete all files together sys fld csv DALO fld log file Log file for reading out data in Fronius Solar access You...

Страница 45: ...re written within approx 7 months CSV data size of approx 8 MB To avoid a loss of data the CSV file should be backed up to a PC within these 7 months and deleted from the USB thumb drive If the loggin...

Страница 46: ...mory requires a constant power supply If there is an AC power outage during operation all data in the buffer memory is lost The automatic night switch off must be deactivated so that data is not lost...

Страница 47: ...also function at low tem peratures for outdoor applications USB Stick for Updating Invert er Software The USB stick can be used to help end customers update inverter software via the USB menu item in...

Страница 48: ...nnual check to ensure that all screw connections are tightly fastened Maintenance and service work may only be carried out by Fronius trained service technicians Cleaning Wipe the inverter if necessar...

Страница 49: ...been in stalled in a dark or shaded area Two serial number stickers are en closed with the Installation Instruc tions for the inverter 57 x 20 mm 67 x 20 mm The customer can attach these stick ers th...

Страница 50: ...50...

Страница 51: ...51 EN US...

Страница 52: ......

Отзывы: