32
CONTRAST
Contrast setting on LCD display
Since contrast depends on temperature, it may be necessary to adjust the "CONTRAST"
menu item when ambient conditions change.
LIGHT LCD
Initial setting for display illumination.
The 'ON' setting is identical to the 'AUTO' for battery operation to prevent premature battery
discharge.
CHECK RF
Tests the wireless connection to the inver-
ters.
Scroll through the available inverters using
the ‘Up’ and ‘Down’ keys.
Unit
-
Setting range
0 - 7
Factory setting
7
Unit
-
Setting range
AUTO / ON / OFF
Factory setting
AUTO
AUTO:
The display illumination will stop 10 seconds after the last time
a key has been pressed.
ON:
The display illumination will be permanently on.
OFF:
The display illumination will be permanently off.
Display range
IG01, IG02 - max. IG15;
RF OK IGxx
or
NO RF IGxx
RF OK IGxx
The wireless connection is functioning properly for the selected
inverter.
NO RF IGxx
The wireless connection with the selected inverter has been in-
terrupted or the selected inverter is out of range.
See also "Troubleshooting."