74
Input data
IG 40
IG 60
IG 60 HV
Recommended PV power
3500-5500 Wp
4600-6700 Wp
4600-6700 Wp
MPP-voltage range
150 - 400 V
Max. input voltage
(at 1000 W/m² / - 10°C in no-load)
500 V
500 V
530 V
Max. input current
29,4 A
35,84 A
35,84 A
Output data
IG 40
IG 60
IG 60 HV
Nominal output power (P
nom
)
3,5 kW
4,6 kW
4,6 kW
Max. output power
4,1 kW
5 kW
5 kW
Nominal mains voltage
230 V, +10 / -15 % *
Nominal output current
15,22 A
20 A
20 A
Nominal frequency
50 +/-0,2 Hz *
Total harmonic distortion
< 3%
Power factor
1
General data
IG 40
IG 60
IG 60 HV
Maximum efficiency
94,3 %
94,3 %
94,3 %
Euro-efficiency
93,5 %
93,5 %
93,5 %
Consumption during night
0,15 W *
Consumption during operation
12 W
Cooling
controlled forced ventilation
Protection type (indoor/outdoor housing)
IP 21 / IP 45
Size l x w x h
610 x 344 x 220 mm / 733 x 435 x 225 mm
Weight
16 kg / max. 22 kg
Admissible ambient temperature
(at 95% rel. humidity)
-20 ... 50 °C **
Protection devices
IG 40
IG 60
IG 60 HV
DC-isolation monitoring
Warning / Shut-off
***)
when R
ISO
< 500 kilohms
DC-excess voltage protection
integrated
DC reverse polarity protection
integrated
Reaction at DC-overload
shift of operating point
*)
Values given are standard. Your FRONIUS IG unit has been specifically adjusted in
accordance with the regulations of your country.
**)
The AC-output reduces (power-derating) when the ambient temperature is increased, from
approx. 35 °C (dependent on the solar module voltage).
***)
Depending on the country setup
Fronius IG 40 /