11
EN
The electrode (rod electrode, tungsten electrode, welding wire, etc.) must
-
never be immersed in liquid for cooling
-
Never touch the electrode when the power source is switched on.
Double the open circuit voltage of a power source can occur between the welding elec
-
trodes of two power sources. Touching the potentials of both electrodes at the same time
may be fatal under certain circumstances.
Arrange for the mains cable to be checked regularly by a qualified electrician to ensure the
ground conductor is functioning properly.
Protection class I devices require a mains supply with ground conductor and a connector
system with ground conductor contact for proper operation.
Operation of the device on a mains supply without ground conductor and on a socket with
-
out ground conductor contact is only permitted if all national regulations for protective sep
-
aration are observed.
Otherwise, this is considered gross negligence. The manufacturer shall not be held liable
for any damage arising from such usage.
If necessary, provide adequate earthing for the workpiece.
Switch off unused devices.
Wear a safety harness if working at height.
Before working on the device, switch it off and pull out the mains plug.
Attach a clearly legible and easy-to-understand warning sign to the device to prevent any
-
one from plugging the mains plug back in and switching it on again.
After opening the device:
-
Discharge all live components
-
Ensure that all components in the device are de-energised.
If work on live parts is required, appoint a second person to switch off the main switch at
the right moment.
Meandering weld
-
ing currents
If the following instructions are ignored, meandering welding currents can develop with the
following consequences:
-
Fire hazard
-
Overheating of parts connected to the workpiece
-
Irreparable damage to ground conductors
-
Damage to device and other electrical equipment
Ensure that the workpiece is held securely by the workpiece clamp.
Attach the workpiece clamp as close as possible to the area that is to be welded.
Position the device with sufficient insulation against electrically conductive environments,
e.g. Insulation against conductive floor or insulation to conductive racks.
If distribution boards, twin-head mounts, etc., are being used, note the following: The elec
-
trode of the welding torch / electrode holder that is not used is also live. Make sure that the
welding torch / electrode holder that is not used is kept sufficiently insulated.
In the case of automated MIG/MAG applications, ensure that only an insulated wire elec
-
trode is routed from the welding wire drum, large wirefeeder spool or wirespool to the wire
-
feeder.
Содержание FK 5000
Страница 2: ...2...
Страница 4: ...4...
Страница 18: ...18...
Страница 19: ...General...
Страница 20: ......
Страница 25: ...Connections and mechanical compo nents...
Страница 26: ......
Страница 28: ...28...
Страница 29: ...Installation and commissioning...
Страница 30: ......
Страница 35: ...35 EN 1 2 1 3 3 2 4 5 6 1 4...
Страница 40: ...40...
Страница 41: ...Troubleshooting...
Страница 42: ......
Страница 47: ...Care maintenance and disposal...
Страница 48: ......
Страница 56: ...56...
Страница 57: ...Technical data...
Страница 58: ......