![Fromm P329 A/A Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/fromm/p329-a-a/p329-a-a_operation-manual_2338851017.webp)
PAGE 17 OF 26
0118 IH-7184
17
P329 M_HA mane.fm
Assembly advise
• During assembling move the strap guide plate P32.8118 downwards against the holding gripper.
• Pay attention to the fitting position of the cutter (see drawing).
• Safe the screws N1.1305 with Loctite 222.
• Lubricate the rocker and the bolt P32.1028 in the area of the welding gripper with Klüber Isoflex NBU 15.
• Lubricate the balls, ball cage and the running surface of the balls on the welding gripper with Klüber Isoflex
Alltime SL2.
• Lubricate the cutter and the driver with Mobilux EP2.
9.3 Adjustment of the coupler
The coupler is adjusted in our works.
In case of replacing the seesaw lever, the coupler or the lever body, the coupler has to be readjusted.
Procedure as follows:
The battery is removed from the tool.
The coupler is fitted into the tool.
• Loosen screw N1.1553.
• Displace thrust piece, so that it touches the two
seesaw levers without moving them.
• Re-tighten screw N1.1553.
Control:
The thrust piece must touch the seesaw levers (X1).
Both guide pins must sit on the welding stop
gripper (X2).
10 CLEANING
Clean strap gripping parts from strap abrasion
regularly using compressed air.
Thus also the cover can be removed and with a
suitable air gun air been blown on the welding
elements.
Do not use any mechanical tool for cleaning.
When cleaning the surface of the tool do not use water
or aggressive solvents!
11 SERVICE
Servicing and repair work must only be carried out by authorized service centres.
If the tool breaks down or does no longer operate do not disassemble it. Send it fully assembled to the local
service centre (see name and address on the rear page of this manual). Use original packing.
In order to prevent damages to the motor shaft the two needle free wheeling N3.4509/N3.4520 have to
be replaced after maximum 80 000 strapping cycles.
The battery powered plastic strapping tool P329 is a high performance tool. We strongly recommend you to
have it serviced by an authorized service shop after 12 months at the latest if used one shift per day. If used
two or more shifts per day the tool has to be serviced after a shorter period of time.
N1.1553
X1
X2
Coupler
Thrust piece
Seesaw lever
Guide pin
Welding stop
gripper