10 Trouble-Shooting
The
SG-1300
does not fog
• Check
external
control
signals
• Check
mains
supply
• Check
fluid
tank
(empty?)
• Check
for
correct
connections
at
the
fluid
bottle
• Check
for
fluid
in
the
fluid
tube
•
Check if fluid filter is clogged
The
SG-1300
fogs uncontrollably
• Check
mains
supply
•
Check unit for moisture (moisture inside the machine, especially on the PCB can cause
fogging)
The SG-1300
switches off suddenly
•
The “Temperature cutout” has switched off due to overheating. Remove external heat
source (for instance projector shining right onto the housing) and/or make sure sufficient fresh air
supply. After 15 to 30 minutes the unit should switch back to “on” again.
Loud droning sound during fogging
•
The pump is running dry. Avoid this absolutely!
• Refill
fluid
bottle
•
Double check connection fluid tube and fluid bottle.
E-4 appears on the LED display
•
The machine is getting too hot. The heating switches off and the machine cools down.
Solution:
Disconnect the machine from the main supply for a moment and then re-connect it.
E-1/E-2/E-3 appears on the LED display
•
Please send the machine to the service-station or your local dealer.