19
9.9.1
Measurement of the Impeller–Pump Casing Clear-
ance
Prerequisites
– Pump cover has been removed.
– Pump casing is connected firmly to the lantern.
– The impeller has been mounted and the impeller nut tight-
ened.
Procedure
1. Measure the clearance Z between the pump casing
and
the impeller
using vernier calipers.
Fig. 27
Measurement of pump casing–impeller clearance
2. Compare the clearance Z with
9.9.2
Measurement of the Impeller–Pump Cover Clear-
ance
Prerequisites
– Pipe on discharge line fitting has been detached.
– Pump casing is connected firmly to the lantern.
– Impeller has been mounted without plastic snap ring
.
– Impeller nut has been tightened.
Procedure
1. Pick up the leaf feeler gauge.
2. Measure the clearance inside the pipe connection (discharge
Fig. 28 "Measurement of impeller–pump cover clear-
.
Fig. 28
Measurement of impeller–pump cover clearance
3. Compare the clearance X with
.
9.10 Pump Head Attachment
The pump assembly is dependent on the respective pump mod-
el and size as well as the respective shaft seal. To determine
which shaft seal you have, please see the
Order-Related Docu-
ments
.
Incorrect Elastomers
Pump leakiness.
Ensure that the elastomers are appropriate for the condition
of the pumping medium. Please refer to the
Order-Related
Documents
.
Z
46
47
Pump Size
Clearances [mm]
Z
Impeller–Pump Casing
X
Impeller–Pump Cover
711/712
9.5
0.5
3521/3522
22.5
3531/3532
24.5
3541/3542
19.5
3551/3552
22.5
Table 7
Clearances