15
Fig.
21
Measuring the clearance stationary bushing / pump casing
2. Distance B, use vernier calipers to measure the hub of the
impeller.
Fig.
22
Measuring the impeller
3. Calculate the clearance (clearance = A – B).
4. Compare clearance with
.
9.7.2
Measure the clearance impeller pump cover / pump
type FSM
Procedure
1. Measure the clearance Z between the pump casing
and
the impeller
using vernier calipers.
Note: In order to measure distance Z, the impeller must be
pulled to the front in the direction of the pump casing.
Fig.
23
Measurement of pump casing–impeller clearance
2. Compare clearance Z with
.
9.7.3
Measure the clearance impeller pump cover / pump
type FSM
Prerequisites
– Pipe on discharge line fitting has been detached.
– Pump casing is connected firmly to the lantern.
– Impeller has been mounted without plastic snap ring
.
– Impeller nut has been tightened.
Procedure
1. Pick up the leaf feeler gauge.
2. Measure the clearance inside the pipe connection (discharge
line). See
"Measurement of impeller–pump cover clear-
Pump size
Clearance [mm]
Impeller / pump casing
711/712
0.5
721/722
1.0
741/742
1.5
3531/3532
1.7
3541/3542
1.0
Table
6
Standard
clearance
A
38
37
B
40
41