Page 13
- 10 -
5-3 Replacement of Door Assembly
5-3-1 Removal of Door “C”
Open the door and remove the door by
pulling up from hinge holes.
Door "A"
Door "C"
5-3-2 Removal of Door “E”
Following the procedure as shown in the figure,
insert and bend a thin metal plate between Door
“E” and Door “A” until you hear the ‘tick’ sound.
● Insertion depth of the thin metal plate should be
0.5mm or less.
5-3-3 Removal of Key Door & Spring
Remove pin hinge from Door “E”.
Detach spring from Door “E” and key door.
5-3-4 Reassembly Test
After replacement of the defective component parts of the door, reassemble it and follow the
instructions below for proper installation and adjustment so as to prevent an excessive microwave
leakage.
1. When mounting the door to the oven, be sure to adjust the door parallel to the bottom line of the oven face
plate by moving the upper hinge and lower hinge in the direction necessary for proper alignment.
2. Adjust so that the door has no play between the inner door surface and oven front surface. If the door
assembly is not mounted properly, microwave energy may leak from the space between the door and oven.
3. Do the microwave leakage test.