Under-Cabinet Hood

PL36WC41E C    

36" Wall Mount

USA

 • 

10200 David Taylor Drive

 • 

Charlotte, NC 28262

 • 

1-800-FRIGIDAIRE

 • 

frigidaire.com

 

CANADA

 • 

5855 Terry Fox Way

 • 

Mississauga, ON L5V 3E4

 • 

1-800-265-8352

 • 

frigidaire.ca

PL36WC41E 01/11 

© 2011 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Specifications  

subject to change.

Under-Cabinet Hood Specifications

 Product Shipping Weight (Approx.) – 32 Lbs.

• 

Wall-Mount Installation – can be ducted vertically or horizontally.

 Ventilation system is preset to recirculate air inside with no ducting 

system required. Exhausting air outside is optional, using either 

vertical or horizontal ducting system. 

(Refer to Ducted Option 

Specifications for outside ventilation.)

• 

Sones Rating – 4.5

• 

Voltage Rating – 120V / 60 Hz / 15 Amps

• 

Connected Load (kW Rating) @ 120 Volts = TBD  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

• 

Amps @ 120 Volts = 3.0 Amps

• 

Always consult local and national electric codes. Check local building 

codes for installation requirements, as they may vary per locale.

• 

Connect vent hood with copper wire only.

• 

Minimum installation height allowed from top of hood to cooking 

surface is 24" - 30".

• 

To improve performance, optional Duct-Free Kit recommended for 

use with recirculating system.

• 

Installation on recessed-bottom cabinets requires attachment of two 

wood filler strips at each side of recessed area under cabinet.

Ducted Option Specifications

• 

For outside ventilation. 

• 

Exhaust Duct Required – 3-1/4" x 10" 

(3-1/4" x 10" to 6"-round transition 

duct can be used if needed)

 

• 

For most efficient airflow exhaust, use a straight run or as few elbows 

as possible.

• 

Use metallic flex ducting only to connect rigid duct directly to 

transitions

 (if allowed by code).

• 

Thermal breaks such as short section of nonmetallic duct, should be 

used in areas of extreme cold.

• 

Cold weather installations should have additional backdraft damper 

installed.

 Refer to installation instructions on web for detailed duct preparation and 

converting exhaust vent blower system for exterior exhaust ventilation.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Optional Accessories

 Duct-Free Kit (Single-Pack) – (PN # 5304455850).

 Duct-Free Kit (8-Pack) – (PN # DFKIT368PK).

 Damper Kit (6-Pack) – (PN # DAMPKIT6PK).

 7"- Round Damper Kit (Single-Pack) – (PN # 5304455851).

Under-Cabinet Vent Hood

PL36WC41EC

Frigidaire Baseline

20"

1

/

4

"

Top or rear power

supply locations

7" Round or

1

/

4

" x 10" rectangular

duct location (top)

1

/

4

" x 10" Rectangular

duct location (rear)

36

"

36"

 13"

max.

cabinet

depth

Exhaust Options

Vent hood can be vertically or horizontally

ducted outside using round or rectangular duct; or

recirculated inside with no ducting required.

For detailed duct preparation and installation

specifications, refer to installation

instructions on web.

Outside Horizontal – 

3

1

/

4

" x 10"Rectangular Duct

5

1

/

4

" 5

1

/

4

"

3

3

/

4

"

Cabinet Front

1

/

8

"

7

1

/

2

"

Electrical

access hole

(in wall)

3

/

4

"

Horizontal

duct cutout (in wall)

3

/

8

"

Wood filler strips

Minimum 24"-30"

allowed from cooking surface

to top of hood

1

1

/

4

"

Outside Vertical – 

3

1

/

4

" x 10"Rectangular Duct

Cabinet Bottom

5

1

/

4

"

5

1

/

4

"

7

1

/

2

"

Vertical

duct

cutout

2"

9"

Electrical access hole (in cabinet bottom)

5"

9"

1

1

/

2

"

16 

15

/

16

"

16 

15

/

16

"

Wood filler strips (recessed cabinet bottoms only)

1

1

/

2

"

Outside Vertical – 

7"Round Duct

Cabinet Bottom

5"

8"dia.cutout

for 7"round

duct

2"

Electrical access hole (in cabinet bottom)

7

1

/

2

"

16 

15

/

16

"

16 

15

/

16

"

Wood filler strips (recessed cabinet bottoms only)

9"

1

1

/

2

"

9"

1

1

/

2

"

Содержание PL36WC41EC

Страница 1: ...al or Horizontal Air Delivery CFM 400 Blower Type Centrifugal Fan Speeds 3 Cooktop Light s 2 Halogen Dishwasher Safe Filter s Yes Exhaust Duct Convertible2 Duct Required 7 Round or 3 1 4 x 10 Optional Accessories Duct Free Kit Single Pack PN 5304455850 Duct Free Kit 8 Pack PN DFKIT368PK Damper Kit 6 Pack PN DAMPKIT6PK 7 Round Damper Kit Single Pack PN 5304455851 Specifications Product Dimensions H...

Страница 2: ...ow exhaust use a straight run or as few elbows as possible Use metallic flex ducting only to connect rigid duct directly to transitions if allowed by code Thermal breaks such as short section of nonmetallic duct should be used in areas of extreme cold Cold weather installations should have additional backdraft damper installed Refer to installation instructions on web for detailed duct preparation...

Страница 3: ...8352 frigidaire ca INSTGDLNS_SSR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front ...

Страница 4: ...5 8352 frigidaire ca INSTGDLNS_TMR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...

Отзывы: