GAS SUPPLY REQUIREMENTS

1. Installation 

MUST 

conform with local codes, or in the

    absence of local codes, with the National Fuel Gas
    Code, ANSI  Z223.1 (latest edition) or in Canada, the
    current AN/CGA B149.
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3.  If codes allow, flexible metal tubing may be used to connect
     your dryer to the gas supply line. The tubing 

MUST 

be

     constructed of stainless steel or plastic-coated brass.
4. The gas supply line 

MUST 

have an individual shutoff valve.

5. A 1/8 inch (0.32 cm) N. P. T. plugged tapping, accessible
    for test gage connection, 

MUST 

be installed immediately

    upstream of the gas supply connection to the dryer.
6. The dryer and its individual shutoff valve 

MUST 

be

     disconnected from the gas supply piping system during
    any pressure testing of the gas supply piping system at
   test pressures equal to or less than 1/2 psig (3.45 kPa).
7. The dryer 

MUST 

be isolated from the gas supply piping

     system by closing its individual manual shutoff valve during
    any pressure testing of the gas supply piping system at
   test pressures equal to or less than 1/2 psig (3.45 kPa).

LOCATION OF YOUR LAUNDRY CENTER

DO NOT INSTALL YOUR LAUNDRY CENTER:

1. In an area exposed to dripping water or outside weather
     conditions.
2. In an area where it will come in contact with curtains or
    drapes.
3. On carpet. Floor 

MUST 

be solid with a maximum slope of 1

    inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET

1. A laundry center installed in a bedroom, bathroom, recess
    or closet, 

MUST 

be exhausted outdoors.

2. No other fuel burning appliance shall be installed in the
    same closet as the 

Gas 

laundry center.

3. Your laundry center needs the space around it for proper
    ventilation.

     DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET
    WITH A

 

SOLID DOOR.

4. A minimum of 120 square inches (774.2 square cm) of
    opening, equally divided at the top and bottom of the door,
    is required. Air openings are required to be unobstructed
    when a door is installed. A louvered door with equivalent
    air openings for the full length of the door is acceptable.

5. The following illustrations show minimum clearance
     dimensions and air openings for proper operation in a recess
    or closet installation.

MOBILE HOME INSTALLATION

1. Dryer 

MUST 

be exhausted outside (outdoors, not

    beneath the mobile home) using metal ducting that
    will not support combustion. Metal ducting must be 4
    inches (10.16 cm) in diameter with no obstructions.
    Rigid metal duct is preferred.
2. If dryer is exhausted through the floor and area beneath
     the mobile home is enclosed, the exhaust system 

MUST

    terminate outside the enclosure with the termination
    securely fastened to the mobile home structure.
3. Refer to page 3 for other important venting requirements.

4. When installing a gas dryer into a mobile home, a
    provision must be made for outside make up air. This
    provision is to be not less than twice the area of the
    dryer exhaust outlet.
5. Installation 

MUST 

conform to current Manufactured

    Home Construction & Safety Standard (which is a
    Federal Regulation Title 24 CFR-Part 32-80) or when
     such standard is not applicable, with American National
    Standard for Mobile Homes. In Canada, the CSA Z240
    is applicable.

                            

   The laundry center is designed under

ANSI Z 21.5.1 for 

HOME USE 

only.

4

0 IN.

(0 CM)

DRYER

WASHER

0 IN.

(0 CM)

1 IN.

(2.54  CM)

0 IN.

(0 CM)

60 SQ. IN.

(387.1 SQ. CM)

60 SQ. IN.

(387.1 SQ. CM)

:$51,1*

60 SQ. IN.

(387.1 SQ. CM)

60 SQ. IN.

(387.1 SQ. CM)

Closet Door

Содержание GLET1142CS0

Страница 1: ... for commercial applications such as restaurants or beauty salons etc For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light a...

Страница 2: ... pounds per square inch maximum unbalance pressure hot vs cold 10 psi Your water department can advise you of your water pressure The hot water temperature should be about 140 degrees F DRAIN REQUIREMENTS 1 Drain capable of eliminating 17 gals per minute 2 A standpipe diameter of 1 1 4 inches 3 18 cm minimum 3 The standpipe height above the floor should be Minimum height 33 inches 83 82 cm Maximum...

Страница 3: ...ate the duct outdoors and seal all joints with duct tape All male duct pipe fittings MUST be installed downstream with the flow of air Explosion hazard Do not install the laundry center where gasoline or other flammables are kept or stored If the laundry center is installed in a garage it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death explosion fire or ...

Страница 4: ...e Gas laundry center 3 Your laundry center needs the space around it for proper ventilation DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET WITH A SOLID DOOR 4 A minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for th...

Страница 5: ...e the wire shipping clips securing the drain hose and power cord if equipped Plastic clamps secure the drain hose to the right side of the washer backsheet These clamps form a standpipe to prevent water syphoning DO NOT REMOVE THESE CLAMPS 6 Carefully move the laundry center to within 4 feet 1 22 m of the final location to begin the installation 5 25 IN 64 13 CM 3 IN 9 52 CM 4 13 16 IN 12 22 CM 9 ...

Страница 6: ...akdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your laundry center is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances If in d...

Страница 7: ...ard so the rear legs are off the ground Gently set the laundry center back down to allow the rear legs to self adjust Place a level on top of the washer Check it side to side then front to back Screw the front leveling legs up or down to ensure the laundry center is resting solid on all four legs no rocking of the laundry center should exist NOTE Keep the leg extension at a minimum to prevent exce...

Страница 8: ...dren might use them for play Cartons covered with rugs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this laundry center are not meant to cover every possible condition and situation that may occur Good safe pra...

Отзывы: