background image

2

4. CHECK FOR ANYTHING THAT COULD BLOCK

AIRFLOW - check area outside of window for things

such as shrubs, trees, or awnings. Inside, be sure

furniture, drapes, or blinds will not stop proper airflow.

5.

Check the available electrical service

- power supply must

be the same as that shown on the unit serial nameplate.

(See Owner’s Guide for serial plate location.) Power cord

is 48''long. Be sure you have an outlet near.

All models have a 3-prong service plug to provide proper

service and safe positive grouding. Do not change plug in

any way. Do not use an adapter plug. If your present wall

outlet does not match your plug, call a qualified electrician

to make the needed change.

6.

Carefully unpack air conditioner

- remove all packing

material. Protect floor or carpet from damage. Two

people should be used to move and install unit.

Tools Required

a large flat blade screwdriver

tape measure

adjustable wrench or pliers

pencil

Level

Socket wrenches

Phillips screwdriver

Hardware (in plastic bag)

Qty.

2

3

1

4 ea.

2 ea.

2

10

Washer Head
Locking Screw
For window panels

3/4'' Long Hex-
Head Screw

Safety Lock

1/2'' Long Screw
and Locknut

3/4'' Long Flat
Head Bolt and
Locknut

Sill Angle Bracket

Long hex-head
locking screw for
top angle, side
retainer 5/16''
Long

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Grounding type wall
receptacle

Do not, under any
circumstances, cut,
remove, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Содержание GAM155Q1A - GIBSON 15100BTU 115V 12.5A 10.3 SPD 4 WAY AIR DIRECTION

Страница 1: ...ly hold the needed screws If not make repairs before installing unit 3 Check your storm windows if your storm window frame does not allow the clearance required correct by adding a piece of wood as shown in FIG 2 or by removing storm window while room air conditioner is being installed continued STORM WINDOW FRAME OR OTHER OBSTRUCTION BOARD THICKNESS AS REQUIRED ALONG ENTIRE STOOL FASTEN WITH TWO ...

Страница 2: ...refully unpack air conditioner remove all packing material Protect floor or carpet from damage Two people should be used to move and install unit Tools Required a large flat blade screwdriver tape measure adjustable wrench or pliers pencil Level Socket wrenches Phillips screwdriver Hardware in plastic bag Qty 2 3 1 4 ea 2 ea 2 10 Washer Head Locking Screw For window panels 3 4 Long Hex Head Screw ...

Страница 3: ... Pull down front panel and remove filter See FIG 1 2 Lift front upwards and place to one side 3 Locate the four front screws and remove These screws will be needed to re install the front later See FIG 2 4 Pry away front from cabinet sides as per photo See FIG 3 5 Gently lift front off unit and place to one side See FIG 4 6 Remove shipping crews from top of unit and also on the side by the base if...

Страница 4: ...f sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill and remove 2 Assemble sill angle bracket to support brackets at the marked position as shown Hand tighten but allow for any changes later 3 Install support brackets with sill angle brackets attached to correct hole in bottom of cabinet as shown 4 Tighten all 6 bolts securely MARK LEFT LOCKNUT SILL ANGLE BRACKET...

Страница 5: ...r sashes 2 Attach right angle safety lock as shown 7 LOCKING SCREWS WINDOW SASH SEAL SAFETY LOCK 3 4 long hex head screw 8 Extend Window Filler 6 Panels and Sash Seal Install Window Lock Install Chassis into Cabinet and Install Front to Unit 3 Be sure chassis is firmly seated towards rear of cabinet Installation of front is the reverse of removal outlined in Section 1 2 DO not push on controls OR ...

Страница 6: ...alled 4 faces and is not blocked to the area to be cooled 5 allows unblocked airflow from rear sides and end outside of installed air conditioner 1 Prepare wall in frame construction including brick and stucco veneer Working from inside the room find wall stud nearest the center of area where air conditioner will be installed by sounding wall or by magnetically finding nails 2 Cut or knock out a h...

Страница 7: ...in the bottom of the channel resting on frame See FIG 2 following 3 1 LONG WOOD SCREW FIG 2 Refer to Step 4 of Window Mounting for assembly of support brackets A wooden strip nailed to the outside wall should be used in conjunction with sill support angle brackets 5 Screw or nail cabinet wooden frame using shims if frame is oversized to eliminate distortion Remember to maintain proper slope as des...

Страница 8: ...is to build an in between frame of 2x4 s as shown in the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored to masonry wall opening This way gives very good louver clearance on either side of cabinet 3 Install a lintel to support masonry wall above cabinet Existing holes in cabinet can be u...

Отзывы: