Test

Test

Check

Correction

1. Is the water level above 4.5 inches?

2. Does water enter the washer continuously.

3. Remove power from washer. Does the water

stop coming in?

4. Replace the pressure sensor switch. Did this

correct the problem?

1. Is the loading door closed?

2. Disconnect the plug from J2 on the control

board and check for continuity between the
pins in the plug.

1. Remove power from the washer. Wait one

minute. Can you open the door?

1. Remove the door lock assembly and

measure the resistance of the PTC.

1. Disconnect the plug from the drive motor and

measure the resistance pins 4 & 5 in the motor.

1. Remove the belt from the motor and spin the

motor pulley. Does the motor spin free?

2. Spin the tub pulley. Does the tub spin free?

3. Disconnect the plug from the motor and

measure the resistance of the windings (pin
1 to pin 2, pin 1 to pin 3, pin 2 to pin 3). All
readings should be between 4 and 6 Ohms.

1. Remove the belt from the motor and spin the

motor pulley. Does the motor spin free?

2. Spin the tub pulley. Does the tub spin free?

3. Disconnect the plug from the drive motor and

measure the resistance between pins 4 & 5
in the motor.

4. Disconnect the plug from the motor and

measure the resistance of the windings (pin
1 to pin 2, pin 1 to pin 3, pin 2 to pin 3). All
readings should be between 4 and 6 Ohms.

1. Communication problem. Check the wiring

between the control board and the speed
control board.

1. Check the resistance of the NTC. Is it

around 50K ohms?

1. Have the power company check the

frequency of the incoming power. If correct,
replace the control board.

Test 6:

Test 7:

Test 8:

Test 9:

Test 10:

Test 11:

Test 12:

Test 13:

Test 14:

Test 15:

Yes. Go to step (2).
No. Go to step (4).
Yes. Go to step (3).
No. Replace the control board.
No. Replace water valve assembly.
Yes. Check wiring to valve assembly for shorts. If
wiring is good, replace the control board.
Yes. Problem solved.
No. Replace the control board.
No. Close the door.
Yes. Go the step (2).
Open. Check the door strike. If good, replace the
door switch assembly.
Closed. Replace the control board.
Yes. Replace the control board.
No. Replace the door switch assembly.
Note: You may have to break the door strike to do this.

Shorted or open. Defective door lock assembly.
Reads around 1500 Ohms. Defective control board.
If the reading is between 105 & 130 Ohms, replace the
speed control board.
If the meter reads other than between 105 & 130 Ohms,
replace the motor.
No. Replace the motor.
Yes. Go to step (3)
No. Check the tub bearings.
Yes. Go to step (3)
If the readings are correct, replace the speed control
board.
If the readings are incorrect, replace the motor.

No. Replace the motor.
Yes. Go to step (3)
No. Check the tub bearings.
Yes. Go to step (3)
If the meter reads other than between 105 & 130 Ohms,
replace the motor.
If the reading is between 105 & 130 Ohms, Go to step (4)

If the readings are correct, replace the speed control
board.
If the readings are incorrect, replace the motor.

Wiring bad. Correct wiring problem.
Wiring good. Replace the control board. If the problem is
not corrected, replace the speed control board.

No. Replace the water inlet valve assembly
Yes. Replace the control board.

P/N 134730700B (0605)

Содержание FTF2140ES3

Страница 1: ...uttons simultaneously All LEDs will go blank and after a few seconds the control will signal the stored code using audible beeps and blinking LEDs The control will repeatedly signal the code as long as the Start and Pause Cancel buttons are pressed A two second pause between repeats affords you the ability to make accurate counts to identify the correct error codes Please Note the following on a s...

Страница 2: ...ugh the bleach compartment 4 Turn the program knob 3 clicks from the start position The bleach and the wash water solenoids will activate and cold water should enter through the softener compartment 5 Turn the program knob 4 clicks from the start position The door lock solenoid will activate 6 Turn the program knob 5 clicks from the start position The door lock solenoid will deactivate and the loa...

Страница 3: ...r to test 11 E56 High motor current Refer to test 11 E57 High current on inverter Refer to test 11 E58 High current on motor phase Refer to test 11 E59 No tacho signal for 3 seconds Refer to test 12 E5A High temperature on heat sink Replace the speed control board E5B High temperature on heat sink Replace the speed control board E5C High temperature on heat sink Replace the speed control board E5D...

Страница 4: ...to step 2 Zero Replace the control board 120 VAC Remove the pump and check for blockage If blocked remove the restriction if not replace the pump Defective wiring Correct wiring Good wiring Replace the pressure sensor If this does not correct the problem replace the control board 1 Is the incoming water flow normal 2 Are the incoming water faucets turned 3 Is the incoming water pressure above 30 p...

Страница 5: ... 1 Have the power company check the frequency of the incoming power If correct replace the control board Test 6 Test 7 Test 8 Test 9 Test 10 Test 11 Test 12 Test 13 Test 14 Test 15 Yes Go to step 2 No Go to step 4 Yes Go to step 3 No Replace the control board No Replace water valve assembly Yes Check wiring to valve assembly for shorts If wiring is good replace the control board Yes Problem solved...

Страница 6: ...ocké en utilisant les signaux sonores et le clingnotement audibles LED La commande signalera à plusieurs reprises le code aussi longtemps que les boutons d annulation de début et de pause sont pause de pressed A deux la seconde entre les répétitions vous a les moyens la capacité de réaliser des comptages précis pour identifier lescodes d erreur corrects Veuillez noter le suivant sur un nombre rest...

Страница 7: ...upée pendant cet essai la porte peut être ouverte Pour empêcher des dommages ne mettez pas votre intérieur de mains quand le baquet est tourner 10 Turn que le bouton de programme 9 clique dès le début la position La commande signalera le dernier code d erreur Annuler Le Mode Diagnostique Il y a deux options pour annuler le mode de test de diagnostique et ramener la laveuse l opération en fonctionn...

Страница 8: ...Le secteur au dessus de la tension d entrée de 130 VCA Incoming en dessous de la tension de 90 VCA Pompe branchée de drain À beaucoup de savon P N 134730700B 0605 Code d Erreur Condition de panne Vérifier Le tableau de code d erreur Référez vous à l essai 1 Référez vous àl essai 2 Référez vous à l essai 4 Remplacez le tableau de commande Remplacez le tableau de commande Référez vous à l essai 5 Ré...

Страница 9: ...emplacez le tableau de commande 120 VCA Enlevez la pompe et vérifiez le colmatage Si bloqué enlevez la restriction si pas remplacent la pompe Câblage défectueux Câblage corriger Câblage bon Remplacez la sonde de pression Si ceci ne corrige pas le problème remplacez le tableau de commande 1 L écoulement entrant de l eau est il normal 2 Sont les robinets entrants de l eau tournés 3 Est ce que la pre...

Страница 10: ...commande Si leproblème n est pas corrigé remplacez le tableau decommande de vitesse Non Remplacez l ensemble de soupape d admission del eau Oui Remplacez le tableau de commande 1 Is le niveau d eau au dessus de 4 5 pounces 2 Arrose entrent dans la laveuse continuellement 3 Coupez la puissance de la laveuse Fait l arrêtprochain in de l eau 4 Remplacez le commutateur de sonde de pression Est ce que ...

Страница 11: ......

Страница 12: ...6 134730700B ...

Отзывы: