Содержание FRA086HT10

Страница 1: ...ENERAL INFORMATION 2 UNIT FEATURES 3 ELECTRICAL DATA 4 TNSTALLATION 5_7 SYSTEMCONFIGURATION 8 10 MAJOR APPLIANCE WARRANTY 19 AUXILIARY CONTROLS 11 12 14 o o www frigidaire c0m USA 1 866 942 1567 www frigidaire ca Canada 1 866 942 1567 ...

Страница 2: ...nal Frigidaire package terminal air conditioners and heat pumps provide a high standard of quality in performance workmanship durability and appearance as they heat and cool the occupied air space year round This manual provides information for ease of installation operation and maintenance All models are designed for through the wall installation Separate installation instructions are included wi...

Страница 3: ...of 3 minutes Automatic Room Freeze Protection This protection feature will automatically ensure the indoor temperature does not fall below freezing When your PTAC is configured for freeze protection which is the default condition then whenever power is supplied to the unit if the unit senses temperature below 40 I the fan motor and electric heater are turned on and will warm the room to 50 F Freez...

Страница 4: ...E SUPPLY Check voltage supply at outlet For satisfactory results the voltage range must always be within the ranges found on the data information plate Cord connected Units The 250 V field supplied outlet must match the plug for the standard 208 230 V units and be within reach of the service cord The standard cord connected 265 V units require an accessory electrical subbase for operation Refer to...

Страница 5: ...lled on the tube sheets provide a good seal between the grille and outdoor coil tube sheets These foam seals provide a barrier that stops air from the inside mixing with air on the outside known as air recirculation UNIT DAMAGE AND OR OPERATION HAZARD Failure tofollow thiscautionmay result inequipment damage or improperoperation For retrofit applications foam sealson outdoor coil tube sheets must ...

Страница 6: ...l from plastic sleeve See Fig 6 INSTALLATION OF A FRIGIDAIRE WALL SLEEVE USING A NON FRIGIDAIRE GRILLE Using a Frigidaire wall sleeve with a non Frigidaire grille requires installation of an Accessory Baffle Kit see Fig 7 which ensures a good seal between the unit and exterior grille to prevent air recirculation Air recirculation is a large contributor to performance loss and premature damage to m...

Страница 7: ...ange holes See Fig 11 6 Reinstall front panel See Fig 12 UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Failure to remove shipping tape and screw will prevent fresh air vent door from opening and may result in damage to vent door cable Pull out at the bottom to release it from the tabs 1 Then lift up 2 Fig 10 Removing Front Panel Shipping ta ...

Страница 8: ...ull lever through label to operate Fig 13 Ventilation Control Location ADJUSTING AIR DIRECTION FOR DUCTED INSTALLATIONS ONLY To adjust air direction 1 Remove front panel See Fig 10 2 Remove louver screws that hold louver insert in place from back side of front panel See Fig 14 3 Turn louver insert and rotate 180 See Fig 18 4 Replace louver insert 5 Replace screws and front panel NOTE Upward air di...

Страница 9: ... to select set point range When set point limit set display always shows full range 5 6 UP DOWN 63 80 F 18 28 C 7 Freeze Guard Disable 1 Electric Heatinq Only Emergency Heat For Heat Pump Units Only This setting is typically used for Emergency Heating 2 Wall Thermostat Enable A wired wall thermostat can be connected to the unit The dip switch must be adjusted accordingly in order to allow the wall...

Страница 10: ...ture DisplavA Change between showing the setpoint or desired temperature during heating and cooling modes SP or displaying the actual room temperature during heating and cooling modes AA SP mode is the default mode If SP is selected the desired setpoint temperature will be displayed during heating and cooling modes regardless of what the actual temperature is in the room If AA mode is selected the...

Страница 11: ...ermostat Wiring 1 Check to be sure power to unit is disconnected 2 Pull terminal connector to remove NOTE Terminal connector can be removed and replaced to simplify thermostat wiring 3 Connect wires from the thermostat to terminals on unit terminal connector 4 Reinstall terminal connector 5 Ensure that unit is configured for wall thermostat enable 6 Replace control panel label with control panel g...

Страница 12: ...ig 20 and Fig 21 for terminal connections INTELLIGENT SELF CHECKING CONTROL Your Frigidaire PTAC has a computer on board that continuously checks key components of the unit to ensure they are operating properly Under normal operation unit status indicator STATUS on main PCB light is steadily ON If there is a major problem the unit will shut down and display a diagnostic failure code on the unit s ...

Страница 13: ...Ttisused forswitchingbetween Cool Fan and Heat mode 3 A Jsused forincreasing temperature ortimersetting 4 V isused fordecreasingtemperature or timersetting 5 fan speed Itisused forsetting high medium low or auto fan speed The correspondingLED will be lit when selected 6 timer Itisused forsetting timerfunction 2010 Electrolux Home Products Inc All rights reserved 13 ...

Страница 14: ...mer Setting Press timer to set timer function and TIMER icon will be on The time can be adjusted by pressing A or V buttons The range of timer setting is from 0 5h to 24h 5 seconds after timer setting the timer function will be activated and TIMER icon will be on 4 Timer Preview When timer function has been set press timer to preview the remaining time of timer 5 if Timer function has been set tur...

Страница 15: ...er care or lack of maintenance is not covered by warranty Do not operate unit without filters in place If a filter becomes torn or damaged it should be replaced immediately Operating without filters in place or with damaged filters will allow dirt and dust to reach indoor coil and reduce cooling heating airflow and efficiency of unit Airflow restriction may cause damage to unit To maintain unit ef...

Страница 16: ...ever use high pressure spray on coils o Clean basepan and outdoor vent filter Clean outdoor orifice and fan Clean indoor coil Never use high pressure spray on coils Clean indoor fan wire screen and front panel Clean or install new indoor air inlet filter s Clean wall sleeve and outdoor grille Inspect cord and receptacle Secure electrical connections Ensure front panel is properly mounted and not d...

Страница 17: ...furniture are not restricting or blocking unit airflow Reset to a lower or higher temperature setting Remove and clean filters Allow sufficient amount of time for unit to heat or cool the room Start heating or cooling early before outdoor temperature cooking heat or gatherings of people make room uncomfortable Close vent door Check dipswitch settings for desired comfort Wait approximately 3 minute...

Страница 18: ... is drained from the air conditioners CAUTION Avoid Injury or damage to the unit or other property 1 Provide occasional ventilation during use Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively 2 Do not place containers containing water on unit 3 Turn off the air conditioner at the power source when it will not be used for ...

Страница 19: ...ance or facility incurred during installation including but not limited to floors cabinets walls etc 11 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER...

Страница 20: ...66129907342 ...