Frigidaire 27" Combination Installation –

24" Built-In Microwave (with 27" Trim Kit)

Electric Single Wall Oven

Warmer Drawer

27" Combination Installation

Built-In Microwave / Single Wall Oven / Warmer Drawer

27" Combination Installation Specifications

 Always consult local and national electric codes.  

(Refer to product-specific electrical specifications on this page.)

 Minimum 23-5/8" deep cutout dimension is critical for proper 

combination installation, to ensure that each built-in product’s 

faceplate will fit flush against cabinet front.

 Bases must be level and cabinet front must be square.

 Minimum 4-1/2" required distance from bottom of Warmer Drawer 

cutout to floor.

 Respect critical dimensions as noted for proper installation of 

 

built-In products.

 Minimum 21" clearance needed for Wall Oven door depth when open.

27" Built-In Microwave Specifications

 For built-in installation, microwave MUST be installed with optional 

27" Trim Kit which includes Bottom Duct Assembly – shipped in 

separate box, ordered by individual part number. 

 Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

 Connected Load (kW Rating) @ 120 Volts = 1.7 kW 

 

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

 Amps @ 120 Volts = 14.3 Amps

 Full base of solid plywood or similar material required, capable of 

supporting 100 Lbs.

 Minimum 2-7/8" clearance required from bottom of Built-In Microwave 

cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap 

between both product faceplates.  

27" Electric Single Wall Oven Specifications

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 

AC only electrical supply with ground required on separate circuit 

fused on both sides of line.

 For detailed electrical requirements, refer to model-specific product 

page and installation guide on web.

 To support Wall Oven when using in combination with Warmer 

Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base, 

capable of supporting 200 Lbs. Do NOT use full base, since planks  

are necessary to allow for proper air displacement.

27" Warmer Drawer Specifications

• Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = 0.5 kW 

 

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

• Amps @ 120V = 3.8 Amps
• Full base of solid plywood or similar material required, capable of 

supporting 100 Lbs. 

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.