background image

Important Safety Instructions

Grounding type wall
receptacle

Do  not,  under  any
circumstances, cut,
remove, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings. 

WARNING

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following: 

Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.

If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation. 

Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the 
installation instructions for possible future use in removing or reinstalling this unit. 

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
and rear coils.

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements. 

Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.  
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.  

Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.  

Do not use an extension cord or an adapter plug.

WARNING

Electrical Information

WARNING

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.

NOTE:

The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.

2

2009 Electrolux Home Products, Inc.

All rights reserved.

 

 

NOTE:

This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as 
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that 
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. 

SAFETY PRECAUTIONS

This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
Do not insert or place fingers or objects into the air discharge area in the front of the unit.
Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
Do not cut or damage the power cord.
If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized 
Electrolux servicer.
Do not operate the air conditioner with wet hands.
Do not pull on the power cord.
Do not drink any water that is drained from the air conditioner.

DANGER!  Avoid Serious Injury or Death 

Содержание FHWW063WB1

Страница 1: ... Care Care and Cleaning Energy Saving Ideas June 2009 Important Safety Instructions Operating Instructions of your Room Air Conditioner Before You Call Major Appliance Limited Warranty Packaging Normal Sounds Air Conditioner Features Product Registration FCC Statement 12 12 2 4 1 1 7 13 14 7 5 6 6 6 16120300A20672 ...

Страница 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Страница 3: ... not climb on or place objects on outdoor part of the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the air conditioner at the power source when it will not be used for an extended period of time Periodically check the condition of the unit s installation accessories for any damage Do not apply heavy pressure to the radiator fins of the unit Operat...

Страница 4: ... the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be per...

Страница 5: ... This equipment should be installed and operated with minimum 20 cm between the radiator and your body This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC RF exposure statement This Class B digital apparatus complies with Canadian ICES 003 This device complies with Industry Canada license exempt RSS standar...

Страница 6: ...ation Vibration Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Product Registration Product Registration Packaging Normal Sounds Gurgle Hiss Gurgling or hissing noise ma heard due to refrigerant passing through evaporator during normal operation y be Packaging Remove all packaging from inside the carton along with any inserts placed into ...

Страница 7: ...FF SCHEDULE INDICATOR CHECK FILTER RESET BUTTON WIFI This product contains a lithium button coin cell battery If a new or used lithium button coin cell battery is swallowed or enters the body it can cause severe internal burns and can lead to death in as little as 2 hours Always completely secure the battery compartment If the battery compartment does not close securely stop using the product remo...

Страница 8: ...ly go to the highest speed The fan speeds will re adjust back to the slowest speed as the room returns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually YOU WILL SEE Note The display will show the set temperature during normal operation press either up or down button to adjust the set temperature to the desired setting The unit will b...

Страница 9: ... mode We recommend leaving the unit in eco mode to help save energy and money However if you would like to switch out of eco mode touch the button until another mode is selected In eco mode the fan will continue to run for 3 minute after the compressor shuts off The fan then cycles on for 90 seconds at 10 minute intervals until the room temperature is above the set temperature at which time the co...

Страница 10: ...ULT CODES 10 d e v r e s e r s t h g i r l l A c n I s t c u d o r P e m o H x u l o r t c e l E 9 0 0 2 TO CHANGE TEMPERATURE DISPLAY Note The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius YOU WILL SEE DO THIS PRESS AND HOLD THE UP DOWN BUTTONS SIMULTANEOUSLY FOR 3 SECONDS After 60 seconds of control inactivity the display and indicator lights will turn off...

Страница 11: ... The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Fresh Air see Fig 2 3 Exchange air from the room Vent Open see Fig 3 Figure 1 VENT CLOSED Figure 2 FRESH AIR Figure 3 VENT OPEN 6 WAY Air Directional Louvers Air directional louvers control air flow direction Your air conditioner has the louver type described below Slider...

Страница 12: ...checked at least once a month to see if cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Grasp the filter by the center and pull up and out Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or i...

Страница 13: ...occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold coil located behind air filter Straighten away from coil Air from unit does not feel cold enough Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Reset to a lower temperature Noise when unit is cooling Air movement sound This ...

Страница 14: ...ITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW BUT NOT LESS THAN ONE YEAR ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITA...

Отзывы: