Specifications  

subject to change.

Overhead Hood

FHWC3040MS    

30" Under-Cabinet

Under-Cabinet Hood Specifications

• 

Product Shipping Weight (Approx.) – 24 Lbs.

• 

Under-Cabinet Installation – can be ducted vertically or horizontally.

• 

Ventilation system can exhaust air outside, either vertically 

through roof or horizontally through wall. 

(Refer to Ducting Option 

Specifications for outside ventilation.)

. If ducting outside is not 

possible, the system can be alternately set to recirculate air inside, 

requiring use of recirculating kit, included with hood.

• 

Sones Rating – 7.7 

• 

Voltage Rating – 120V / 60 Hz / 15 Amps

• 

Connected Load (kW Rating) @ 120 Volts = .23 kW  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded for 

safe operation.)

• 

Amps @ 120 Volts = 1.8 Amps

• 

Always consult local and national electric codes. Check local building 

codes for installation requirements, as they may vary per locale.

• 

Makeup air systems may be required by local building codes 

when using ventilation systems greater than specified CFM of air 

movement. Specified CFM varies per locale.

• 

Connect vent hood with copper wire only. 

(For installation pre-wired 

with aluminum wiring, refer to Product Installation Guide on web for 

correct wiring procedure.)

• 

Locate vent hood away from strong draft areas, such as windows, 

doors or strong heating vents.

• 

Minimum 24" - 30" installation height allowed from bottom of hood 

canopy to cooking surface; minimum 66" height suggested from  

top of hood to floor.

• 

When installing vent hood under cabinets with recessed bottoms,  

two 2"-wide filler strips required with length and thickness 

determined by recess dimensions.

Ducting Option Specifications

• 

Vent system MUST terminate outside through roof or wall; do NOT 

terminate into attic or other enclosed area.

• 

Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum 

vent length or 7" round with 50' maximum vent length. Refer 

to Product Installation Guide on web for calculations needed to 

determine total duct length.

• 

Installation of 7" Round Duct requires use of 7" Round Transition Duct 

(included) and can only be vented vertically. 

• 

To provide efficient performance, length of vent system and number  

of elbows should be kept to minimum. Flexible vent greatly reduces 

performance and is NOT recommended.

• 

Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent 

recommended; plastic or metal foil vent NOT recommended.

• 

For cold weather installation, additional backdraft damper and thermal 

break should be installed. Thermal break will minimize conduction of 

outside temperatures as part of the vent system with damper on cold 

air side of break, as close as possible to where vent system enters 

heated portion of house.

• 

Refer to Product Installation Guide on web for detailed vent system 

preparation instructions.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Optional Accessories

• 

Charcoal Filter – (PN # 5304486303).

• 

Duct-Free Kit (Single-Pack) – (PN # 5304455849).

• 

Duct-Free Kit (8-Pack) – (PN # DFKIT308PK).

• 

Damper Kit (6-Pack) – (PN # DAMPKIT6PK).

• 

7"-Round Damper Kit (Single-Pack) – (PN # 5304455851).

30" Under-Cabinet Vent Hood (recirculating model)

FHWC3040M

Frigidaire Baseline