background image

3

Save these instructions for future references

Approved for residential appliances

For residential use only

Do not attempt to install or operate your appliance until 

you have read the safety precautions in this manual. 

Safety items throughout this manual are labeled with a 

WARNING or CAUTION based on the risk type.

This is the safety alert symbol. It is used to alert you to

potential personal injury hazards. Obey all safety mes-

sages that follow this symbol to avoid possible injury or 

death.

 

WARNING

This symbol alerts you to situations that may 

cause serious body harm, death or property 

damage.

 

CAUTION

CAUTION indicates a potentially hazardous

situation which, if not avoided, may result in

minor or moderate injury.

 

IMPORTANT

IMPORTANT indicates installation, operation,

maintenance or valuable information that is not hazard

related.

 

IMPORTANT SAFETY INSTRUCTIONS

 

CAUTION

FOR GENERAL VENTILATING USE ONLY. DO NOT 

USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS OR VAPORS.

IMPORTANT SAFETY INSTRUCTIONS

Read all instructions before using this appliance.

 

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

Use this unit only in the manner intended by the 

  manufacturer. If you have questions, contact the 

  manufacturer

Before servicing or cleaning the unit, switch power 

  off at service panel and lock service panel 

  disconnecting means to prevent power from 

  being switched on accidentally. When the service 

  disconnecting means cannot be locked, securely  

  fasten a prominent warning device, such as a tag, to 

  the service panel.

Installation Work and Electrical Wiring Must Be Done 

 %\4XDOL¿HG3HUVRQV,Q$FFRUGDQFH:LWKDOO

 

  Aplicable Codes & Standards, Including Fire-rated 

  Construction.

6XI¿FLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQGH[

 

 KDXVWLQJRIJDVHVWKURXJKWKHÀXH&KLPQH\RIIXHO

 

  burning equipment to prevent back- drafting. Follow  

  the heating equipment manufacturers guideline and 

  safety standards such as those published by the 

   National Fire Protection Association (NFPA), the 

  American Society for Heating, Refrigeration and Air 

  Conditioning Engineers (ASHRAE), and the local code  

  authorities.

When cutting or drilling into wall or ceiling, do not 

  damage electrical wiring and other hidden utilities. 

Ducted systems must always be vented to the  

  outdoors.

A.

B.

C.

D.

E.

F.

 

CAUTION

7RUHGXFHULVNRI¿UHDQGWRSURSHUO\H[KDXVW

DLUEHVXUHWRGXFWDLURXWVLGHGRQRWYHQWH[

-

haust air into spaces within walls, ceilings,  

attics, crawl spaces, or garages.

 

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL

DUCT WORK.

Install this hood in accordance with all requirements 

VSHFL¿HG

Содержание FHWC3025MB

Страница 1: ...USA 1 800 944 9044 www frigidaire com Canada 1 800 265 8352 www frigidaire ca LI30KC 316902495 May 13 ...

Страница 2: ...ome common problems that might occur If you do need service help is only a phone call away Call Frigidaire Customer Services at 1 800 944 9044 Product Registration Registering your product with Frigidaire enhances our ability to serve you You can register online at www frigidaire com or by dropping your Product Registration Card in the mail Serial Plate Location Serial plate location Find it on th...

Страница 3: ... the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation Work and Electrical Wi...

Страница 4: ... DQG ORRVH FORWKLQJ The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all respon sibility for injury due to negligence and the warranty of WKH XQLW DXWRPDWLFDOO H SLUHV GXH WR LPSURSHU PDLQWH nance a b c d 1 2 3 4 IMPORTANT SAFETY INSTRUCTIONS WAR...

Страница 5: ... M91 latest edi tion and all local codes and ordinances If codes permit and a separate ground wire is used it is UHFRPPHQGHG WKDW D TXDOL HG HOHFWULFLDQ GHWHUPLQH WKDW the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 ...

Страница 6: ...the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the stan dard for Manufactured Home Installation 1982 Manu factured Home Sites Communities and Setups ANSI A225 1 NFPA 501A or latest edition or with local codes Cabinet Dimensions A 66 167 cm s...

Страница 7: ...t system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than VSHFL HG 0 RI DLU PRYHPHQW 7KH VSHFL HG 0 YDULHV from locale to locale Consult your HVAC professional for VSHFL F UHTXLUHPHQWV LQ RXU DUHD Venting Methods Vent system can terminate either through the roof or wall Use 3 FP UHFWDQJXODU ...

Страница 8: ...OHU VWULSV LQ locations shown Determine Wiring Hole Location Determine and clearly mark a vertical centerline on the wall and cabinet bottom 1 2 3 4 1 A A Centerline Wood filler strips recessed cabinet bottoms only Wall Cabinet bottom 3 7 6 cm 3 7 6 cm PP mounting screws VENTING REQUIREMENTS 3 FP FP 9HQW 6 VWHP Vent Piece 3 FP FP IW 90 elbow 1 5 m 3 FP FP IW flat elbow 3 7 m 3 FP FP IW wall cap 0 ...

Страница 9: ... System Roof Venting 7R PDNH D ò FP FP UHFWDQJXODU cutout on the underside of cabinet top and bottom Mark lines 1 3 cm and 4 12 1 cm from the back wall on the centerline of the underside of cabinet Mark lines 5 13 3 cm to the right and left of the centerline on the underside of cabinet Use saber or keyhole saw to cut a rectangular opening for vent Repeat steps 1 3 for the underside of the top of t...

Страница 10: ...OH XW 2SHQLQJV IRU ó cm Rectangular Vent Transition to Round Vent Roof Venting To make a circular vent opening on the underside of the cabinet top Mark a centerline on the underside of the top of cabinet Mark a line 5 12 7 cm from the back wall on the underside of the top of cabinet Use a compass or a circle template to draw a circle with a diameter of 7 19 cm Use saber or keyhole saw to cut the c...

Страница 11: ... National Electric Code or CSA standards and local codes and ordinances There must be enough wiring from the fused disconnect RU FLUFXLW EUHDNHU ER WR PDNH WKH FRQQHFWLRQ LQ WKH KRRG HOHFWULFDO WHUPLQDO ER NOTE Do not reconnect power until the installation is complete Remove the screw from the WHUPLQDO ER FRYHU 5HPRYH WHUPLQDO ER FRYHU and set aside Remove the power supply knockout from the top or...

Страница 12: ...Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Disconnect power 2 Use UL listed wire connectors and connect white wires A together 3 Use UL listed wire connectors and connect black wires B together WARNING Fire Hazard Electrically ground the blower Use copper wire Connect ground wire...

Страница 13: ...OTE For installations which are venting out the roof or wall the recirculating vent cover must remain in place Do not remove as unit will not perform properly To complete the installation go to Make Electrical Connection section on page 11 3 4 5 RANGE HOOD USE The range hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking an...

Страница 14: ...SODFH WKH ROG FKDUFRDO OWHU ZLWK D QHZ FKDUFRDO OWHU 4 5 1 2 3 4 5 6 A A Filter screw RANGE HOOD CARE A B A Light bulb socket B Lens cover Cleaning WARNING To Reduce The Risk Of Fire Or Electrical shock disconnect from power supply before cleaning IMPORTANT OHDQ WKH KRRG DQG JUHDVH OWHUV IUHTXHQWO according to the following instructions Replace JUHDVH OWHU EHIRUH RSHUDWLQJ KRRG IMPORTANT WHULRU 6X...

Страница 15: ...t secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective bulb 1 Change the bulb 2 The light bulb is loose 2 Tighten the light bulb 3 The wires on the light switch are loose 3 Make sure the wires on light switch are connected properly The hood is not venting out properly 1 The hood might be hanging to high from the cook top 1 Adjust the distanc...

Страница 16: ...ding the state of Alaska 13 14 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE REPAIR OR REPLACEMENT AS...

Страница 17: ...printed in Mexico ...

Отзывы: