Frigidaire FGTC2349K S Скачать руководство пользователя страница 2

Side-by-Side Refrigerator

FGTC2349K S    

23 Cu. Ft. Counter-Depth

Panel Kit-Ready CD Refrigerator - 23 Cu. Ft.

Gallery

Side-by-Side Refrigerator Specifications

 Panel kit-ready refrigerator doors require installation  

of either optional Door Panel Kit or custom-built door panels.  

(For details, refer to Door Panel Installation on this page.)

 Product Shipping Weight (approx.) – 325 Lbs.

 Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

 Connected Load (kW Rating) @ 120 Volts = 1.02 kW 

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

 Amps @ 120 Volts = 8.5 Amps

 Always consult local and national electric & plumbing codes.

 Floor should be level surface of hard material, capable of supporting 

fully loaded refrigerator.

 When installing refrigerator adjacent to wall, cabinet or other appliance 

that extends beyond front edge of unit, 20" minimum clearance 

recommended to allow for optimum 120° to 180° door swing, providing 

complete drawer / crisper access and removal. 

(Absolute 4-1/2" 

minimum clearance will ONLY allow for 90° door swing which will 

provide drawer / crisper access with restricted removal.)

 To ensure optimum performance, avoid installing in direct sunlight or 

close proximity to range, dishwasher or other heat source.

 For proper ventilation, front grille MUST remain unobstructed.

 Recess electrical outlet when possible.

 Water recess on rear wall recommended to prevent water line damage.

 Water Pressure – Cold water line must provide between 30 and 100 

pounds per square inch (psi).

 Copper tubing with 1/4" O.D. recommended for water supply line  

with length equal to distance from rear of unit to household water 

supply line plus 7 additional feet. Optional Water Supply Installation 

Kits available.

 Adjustable front rollers to assist with door alignment.

“Built-In Look” Specifications

 Minimum opening of 70-1/4" H x 36" W x 25" D required to allow for 

ease of installation, proper air circulation, and plumbing / electrical 

connections.

 If optional Collar Kit (PN # CK23CDS) is to be used, different cutout 

dimensions are required. 

(Refer to Collar Kit CK23CDS Installation 

Specifications page on web.)

 Remove all wall / floor molding prior to installation.

Door Panel Installation

 Removable door trim is designed to accept either optional stainless 

steel Door Panel Kit or custom-built door panels to match cabinetry 

or other decor. 

(For complete custom panel construction and 

installation details, refer to Panel Kit-Ready Refrigerator Door Panel 

Installation page on web; for complete Door Panel Kit installation  

refer to detailed instructions on web or included with kit.)

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Optional Accessories

 Stainless Steel Door Panel Kit – (PN # PK23CDS).

 Stainless Look Collar Kit – (PN # CK23CDS).

Specifications  

subject to change.

FRIGIDAIRE®

USA

 

 250 Bobby Jones Expressway 

 Martinez, GA 30907 

 1-800-FRIGIDAIRE 

 

frigidaire.com

 

CANADA

 

 

5855 Terry Fox Way 

 Mississauga, ON L5V 3E4 

 1-800-265-8352 

 

frigidaire.ca

FGTC2349K  06/09 

© 2009 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Note:

 Optional Collar Kit available to complete  

“built-in look” for Panel Kit-Ready Refrigerator.  

For specifications, refer to Collar Kit (CK23CDS) 

Installation Specifications page on web.

Содержание FGTC2349K S

Страница 1: ... Door Bins Fixed Clear Gallon Door Bin Clear Condiment Bin Freezer 2 Fixed Glass Shelves Space Saver Shelf Full Extension Basket Regular Basket Half Basket 2 Clear Fixed Door Bins 2 Tilt Out Wire Door Shelves ENERGY STAR Sabbath Mode Star K Certified Capacities Total Capacity 22 6 Cu Ft Refrigerator Volume 14 1 Cu Ft Freezer Volume 8 5 Cu Ft Overall Exterior Dimensions Height 69 3 8 Including Hing...

Страница 2: ...commended for water supply line with length equal to distance from rear of unit to household water supply line plus 7 additional feet Optional Water Supply Installation Kits available Adjustable front rollers to assist with door alignment Built In Look Specifications Minimum opening of 70 1 4 H x 36 W x 25 D required to allow for ease of installation proper air circulation and plumbing electrical ...

Страница 3: ...ncluded with kit Custom Built Door Panel Installation Custom door panels can be built to match cabinetry or decor To achieve custom installation refer to detailed Custom Built Door Panel Specifications and Door Panel Installation instructions provided above When building custom door panels 1 4 thick panels will fit door frames with no special preparation panels less than 1 4 will require a spacer ...

Страница 4: ...e panels are used then 1 4 of side panel will extend beyond collar trim and must be finished For detailed refrigerator installation refer to model specific product page and installation guide on web Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Collar Kit CK23CDS Installation Specifications Collar Kit PN CK23CDS is design...

Отзывы: