How to Install

NOTE: 

Top Rail and Side Panels at each side are offset to provide the proper pitch to the rear of (5/16”). 

This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels
for any reason, this pitch to the rear must be maintained!

              Place unit on floor, a bench or a table. There is a Left and Right side Filler Panels - be sure to use the proper
              panel for each side. When installed, the flange for securing the panel in place to the window sill will be facing
              into the room. 

A. Hold the side Panel in one hand and gently pull back the center to free the open end. See FIG. 1. 

B. Slide the free end “T”  section of the panel directly into the cabinet as shown in FIG. 2. Slide the panel down. Be
sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet. 

LEFT + RIGHT FILLER PANEL ASSEMBLY

FIG. 2

FIG. 1

C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by
making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. See
FIG. 3. 
D. Slide the panel all the way in and repeat on the other side.

FIG. 3

2

Installation

Top Rail

Bottom Rail

“T” section

Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches
(584 mm to 914 mm) (FIG. 4A 

 FIG. 4B)

Lower sash must open sufficiently to allow a clear vertical opening of 14 inches (356 mm ). Side louvers and the rear of
the air conditioner must have clear air space to allow enough airflow through the condenser, for heat removal. The rear
of the unit must be outdoors, not inside a building or garage.

Fig. 4A

14

Ǝ

 min

356 mm

Wooden Windows

Fig. 4B

14

Ǝ

 min

356 mm

Vinyl-Clad Windows

INNER
WINDOW SILL

INNER
WINDOW SILL

INTERIOR
WALL

If the air conditoner is blocked by Storm Window, add wood as 
shown in FIG. 5, or remove storm window before air conditioner
is installed. 

If Storm Window Frame must remain, be sure the drain holes or
slots are not caulked or painted shut. Accumulated Rain Water
or Condensation must be allowed to drain out.

Storm Window:

FIG. 5

Board
thickness as
required, for
proper pitch to
rear, along
entire sill. 
Fasten with
nails or screws.

Storm window
frame or other
obstruction.

SASH

1-1/2” min

(38 mm)

Содержание FFRE0833S1

Страница 1: ...tention to danger and safety notices To avoid risk of personal injury property damage or product damage due to the weight of this device and sharp edges that may be exposed Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit Wear protective gloves whenever lifting or carrying the unit AVOID the sharp metal fins of front...

Страница 2: ... ends of the frame into the top and bottom rails of the cabinet See FIG 3 D Slide the panel all the way in and repeat on the other side FIG 3 2 Installation Top Rail Bottom Rail T section Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches 584 mm to 914 mm FIG 4A FIG 4B Lower sash must open sufficiently to allow a clear vertical openin...

Страница 3: ...tensions into the windows sash as shown FIG 9B B For Vinyl Clad windows FIG 8B 3 FIG 7B Drive 1 2Ǝ 12 7 mm locking screws through the frame lock and into the sill FIG 9A NOTE To prevent window sill from splitting drill 1 8Ǝ 3mm pilot holes before driving screws Drive 1 2Ǝ 12 7 mm locking screws through frame holes into window sash FIG 9B FIG 9A FIG 9B Drive locking screws wooden windows Vinyl Clad...

Страница 4: ...er side curtain with the provided ruler as shown FIG 10 Mark a line on the patterned side of the provided insulation panel according to the measured width then cut out the insulation panel along the line as shown FIG 11 Place the patterned side of the insulation panel to face inside your room then slide the insulation panel into the frame until the panel goes into the side curtain frame completely...

Страница 5: ...to spill any condensate water while lifting unit from window Store parts WITH air conditione Weather stripping r normal use correct the slope otherwise FIG 15A FIG 15B FIG 15A Wooden Window E D I S T U O E D I S N I INSIDE about H H Bottom Rail Vinyl Clad Window Bottom Rail OUTSIDE H1 H In order to minimize air leaks between the room air conditioner and the window opening suitable weather strippin...