background image

If These Solutions Fail, Call 1-800-668-4606 For Frigidaire Service.

Before You Call

11

2009 Electrolux Home Products, Inc.

All rights reserved.

Outdoor temperature below 16°C (60°F). To defrost the coil, set FAN ONLY mode.

OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

Plug Current Device Tripped. Press the RESET button.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Control is OFF. Turn Control ON and set to desired setting.

Air conditioner will not operate.

Air conditioner cooling, but room

is too warm - NO ice forming on 

cooling coil behind decorative

front.

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

Temperature is set too high. Set temperature to a lower setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in

front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,

floor and furniture.

Air conditioner turns on and off

rapidly.

Dirty air filter - air restricted. Clean air filter.

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils 

more frequently.

Air conditioner cooling, but room 

is too warm - ice forming

on cooling coil behind decorative

front

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY 

mode.
Temperature is set too low for night-time cooling. To defrost the coil, set to FAN  ONLY mode. Then, 

set temperature to a higher setting.

Room temperature below 16°C (60°F). Cooling may not occur until room temperature rises above 

16°C (60°F).
Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.

Air from unit does not feel cold

enough.

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to 

restart when set in the COOL mode.

Reset to a lower temperature.

Noise when unit is cooling.

Air movement sound. This is normal. If too loud, set to lower FAN setting.

Water dripping INSIDE when

unit is cooling.

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to

installation instructions or check with installer.

Water dripping OUTSIDE when

unit is cooling.

Unit removing large quantity of moisture from humid room. This is normal during excessively humid

days.

Room too cold.

Set temperature too low. lncrease set temperature.

Window vibration - poor installation. Refer to installation instructions or check with installer.

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not 

the result of defective workmanship or materials in this appliance.

Содержание FFRE06W3S14

Страница 1: ... the Use Care Care and Cleaning 10 Energy Saving Ideas 10 16120300A06703 June 2009 Product Registration 4 Packaging 4 Normal Sounds 4 Air Conditioner Features 5 Important Safety Instructions 2 3 Operating Instructions 5 10 of your Room Air Conditioner Before You Call 11 Major Appliance Limited Warranty 12 ...

Страница 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Страница 3: ...e or store flammable gases near the unit CAUTION Avoid Injury or damage to the unit or other property Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply cord will have TWO buttons on the plug head Press the TEST button You will notice a click as the RES...

Страница 4: ...r incorrect installation Vibration Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration 4 Product Registration Packaging Normal Sounds Packaging Remove all packaging from inside the carton along with any ...

Страница 5: ...BATTERY TAB REMOTE CONTROL Operating Instructions NOTE The following instructions represent the Touch Pad the same instructions can be used for the Remote Control TO TURN UNIT ON YOU WILL SEE PRESS ON OFF BUTTON DO THIS Air Conditioner Features Operating Instructions ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER CHECK FILTER RES...

Страница 6: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE TO USE AUTO FAN FEATURE PRESS FAN BUTTON CHOOSE AUTO DO THIS YOU WILL SEE DO THIS PRESS TO SELECT Operating Instructions continued PRESS TO RAISE PRESS TO LOWER DO THIS Note Tap or hold either up or down button unti...

Страница 7: ... During this function the display will show the actual room temperature not the set temperature as in the cooling mode DO THIS PRESS MODE BUTTON Note In this mode the selected temperature will increase by 1 C 30 minutes after the mode is selected The tempe rature will then increase by another 1 C after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns t...

Страница 8: ... must be in the Off position First Press TIMER button then adjust timer setting tap or hold the UP arrow or the DOWN arrow to change delay timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling with maximum Fan speed if Cool Energy Saver or Fa...

Страница 9: ... to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored Fresh Air Vent Control on some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Fresh Air see Fig 2 3 Exchange air from the room Vent Open see Fig 3 Fi...

Страница 10: ...the front panel Air Directional Louvers Air directional louvers control air flow direction Your air conditioner has the louver type described below Auger Type The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed Rotate the Auger Wheels until the desired Left Right direction is obtained Pivot horizontal louvers until the desired Up Down direct...

Страница 11: ...air through cooling coils more frequently Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature is set too low for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a higher setting Room temperature below 16...

Страница 12: ...IS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servi...

Отзывы: