background image

Care and Cleaning & Energy Saving Ideas

13

.

d

e

v

r

e

s

e

r

 

s

t

h

g

ir

 l

l

A

.

c

n

I

 

,

s

t

c

u

d

o

r

P

 

e

m

o

H

 

x

u

l

o

r

t

c

e

l

E

 

9

0

0

2

Energy Saving Ideas

Do not block air flow inside with blinds, curtains or furniture; or outside with

shrubs, enclosures, or other buildings.

The capacity of the room air conditioner must fit the room size for efficient and

satisfactory operation.
Install the room air conditioner on the shady side of your home. A window that faces

north is best because it is shaded most of the day.
Close the fireplace damper, floor and wall registers so cool air does not escape up

the chimney and into the duct work.
Keep blinds and drapes in other windows closed during the sunniest part of the day.
Clean the air filter as recommended in the section “Care and Cleaning”.
Proper insulation and weather stripping in your home will help keep warm air out

and cool air in.
External house shading with trees, plants or awnings will help reduce the air

conditioner’s work load.
Operate heat producing appliances such as ranges, washers, dryers and dishwashers

during the coolest part of the day.

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new. Be sure to unplug

the unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is

necessary. Trapped particles in the filter can build up and cause an accumulation

of frost on the cooling coils.

Grasp the filter by the center and pull up and out.

Wash the filter using liquid dishwashing detergent and warm water. Rinse filter

thoroughly. Gently shake excess water from the filter. Be sure filter is

thoroughly dry before replacing

Or instead of washing, you may vacuum the filter clean.

Push the vent handle to the Vent Closed position(where applicable).

Open the front panel.

Cabinet Cleaning

Be sure to unplug the air conditioner to prevent shock or fire hazard. The

cabinet and front may be dusted with an oil-free cloth or washed with a cloth

dampened in a solution of warm water and mild liquid dishwashing detergent.

Rinse thoroughly and wipe dry.

Never use harsh cleaners, wax or polish on the cabinet front.

Be sure to wring excess water from the cloth before wiping around the controls.

Excess water in or around the controls may cause damage to the air conditioner.
Plug in air conditioner.

Winter Storage

If you plan to store the air conditioner during the winter, remove it carefully from

the window according to the installation instructions. Cover it with plastic or return

it to the original carton.

NOTE: When replacing the air filter after cleaning, make sure the tabs on the air 

filter are on the upper part of filter, and placed outward as shown in the drawing

on the left side.

Tab

Air Filter

Содержание FFRE053WA1

Страница 1: ...Cleaning 13 Energy Saving Ideas 13 June 2009 Product Registration 5 5 g n i g a k c a P Normal Sounds 5 6 s e r u t a e F r e n o i t i d n o C r i A Important Safety Instructions 2 4 2 1 6 s n o i t c u r t s n I g n i t a r e p O of your Room Air Conditioner Before You Call 14 Major Appliance Limited Warranty 15 16120300A22956 ...

Страница 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Страница 3: ... not climb on or place objects on outdoor part of the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the air conditioner at the power source when it will not be used for an extended period of time Periodically check the condition of the unit s installation accessories for any damage Do not apply heavy pressure to the radiator fins of the unit Operat...

Страница 4: ...urring A warning that the appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorises their competence to handle refrigerants safely in accordan...

Страница 5: ...ation Vibration Pinging or Swishing Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration Product Registration Packaging Normal Sounds d e v r e s e r s t h g i r l l A c n I s t c u d o r P e m o H x u l ...

Страница 6: ...nd remote control is pressed after that the unit will beep to indicate it works as the corresponding direction of pressing specific button and the display and LED indicators will illuminate accordingly but they will turn off again in 5 seconds if no further operation Pressing the Light button again will wake up the display and LED indicators WITH DISPLAY REMOTE SENSING BUTTON STANDARD REMOTE NOTE ...

Страница 7: ...automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature See To Operate on Fan Only section on Page 8 COOL FEATURE YOU WILL SEE Note In this mode the fan remains on all the time with the compressor cycling on and off when room temperature is reached CHOOSE COOL DO THIS PRESS MODE BUTTON CHOOSE AUTO DO THIS PRESS MODE BUTTON YOU W...

Страница 8: ...E PRESS FAN BUTTON CHOOSE AUTO DO THIS YOU WILL SEE YOU WILL SEE TO ADJUST FAN SPEEDS Note The fan speed can be selected among four settings Auto Lo Low Med Medium and Hi High unless the unit runs in Auto or Dry mode or the Sleep feature is activated DO THIS PRESS TO SELECT E E S L L I W U O Y Y L N O N A F N O E T A R E P O O T DO THIS PRESS MODE BUTTON CHOOSE FAN ONLY Note Use this function only...

Страница 9: ...ase by 2 F 30 minutes after the mode is selected The temperature will then increase by another 2 F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by a...

Страница 10: ...mote Sensing button again or the main ON OFF button on the unit REMOTE SENSING FEATURE on some models Remote Sensing indicator DO THIS PRESS REMOTE SENSING BUTTON NOTE Remote display is actual temperature at remote control only NOTE Unit display shows the set temperature 10 TIMER DELAY STOP START FEATURE YOU WILL SEE HOW MUCH TIME IS CHOSEN THEN DO THIS PRESS UP DOWN BUTTONS FIRST DO THIS PRESS TI...

Страница 11: ... TO TURN UNIT OFF DO THIS PRESS ON OFF BUTTON TO CHANGE TEMPERATURE DISPLAY DO THIS PRESS AND HOLD THE UP and DOWN BUTTONS TOGETHER FOR 3 SECONDS Note The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius YOU WILL SEE If the display reads AS a sensor has failed Contact your Authorized Frigidaire Service Center FAULT CODES 11 ...

Страница 12: ...return the unit to the same setting once power is restored Fresh Air Vent Control on some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Fresh Air see Fig 2 3 Exchange air from the room Vent Open see Fig 3 Figure 1 VENT CLOSED Figure 2 FRESH AIR Figure 3 VENT OPEN 6 WAY Air Directional Louvers Air directional lo...

Страница 13: ...r filter should be checked at least once a month to see if cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Grasp the filter by the center and pull up and out Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry be...

Страница 14: ... mode Then set temperature to a higher setting 14 Room temperature below 62 F 17 C Cooling may not occur until room temperature rises above 62 F 17 C Temperature sensing element touching cold coil located behind air filter Straighten away from coil Air from unit does not feel cold enough Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when se...

Страница 15: ...WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Service Keep your receip...

Страница 16: ......

Отзывы: