Operating Instructions

Using Air Conditioner

To begin operating the air conditioner, follow these steps:

Set the temperature selector to the highest number (coldest or coolest setting).
Set the mode control to the highest COOL setting.
Adjust the louvers for comfortable air flow (see Air Directional Louvers).
Once the room has cooled, adjust the temperature selector to the setting you
find most comfortable.

Review the “Operating Instructions” section for other settings.

Operating Instructions

The controls featured in this manual are representative of many available

models. Your model may offer slightly different features.

This is used to set the desired room temperature when the unit is being
operated in the “COOL MODE”.

To set the desired room temperature, rotate the selector switch to the desired
setting. After the set temperature is achieved, the thermostat will automatically
start and stop the compressor in order to maintain the desired set temperature.

Rotate the temperature selector clockwise for higher cool setting. Higher cool
settings will provide lower room temperature.
Rotate the temperature selector counter-clockwise for lower cool settings. 
Lower cool settings will provide higher room temperature.

Temperature Selector

Cool Mode

The desired cool setting is selected by rotating the MODE knob to the appropriate location.
     “high cool” has maximum cooling effect and airflow.
     “low cool” has minimum cooling effect and airflow.
Note:If your unit is equipped with a vent handle, keep it closed for maximum efficiency.

Fan Mode

Rotate the MODE knob to select your choice of fan speeds for air circulation only.
Note: When selecting a fan speed, the compressor will not run.

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has the louver
type described below.

Auger Type

Rotate the Auger Wheel until the desired Left/Right direction is obtained.

AUGER WHEEL

(2-WAY)

2009 Electrolux Home Products, Inc.

All rights reserved.

WARNING

Please always wait 3 minutes when turning unit off then on again, and when changing from cool to fan and back to
cool. This prevents compressor from overheating & possible circuit breaker tripping.
Failure to follow these instructions may be harmful to your unit.  

Содержание FFRA0511Q1

Страница 1: ...265 8352 All about the Use Care Care and Cleaning 6 Energy Saving Ideas 6 2020211A2570 June 2009 Product Registration 4 Packaging 4 Normal Sounds 4 Operating Instructions 5 Important Safety Instructions 2 3 of your Room Air Conditioner Before You Call 7 Major Appliance Limited Warranty 8 ...

Страница 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Страница 3: ...utdoor part of the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the air conditioner at the power source when it will not be used for an extended period of time Periodically check the condition of the unit s installation accessories for any damage Do not apply heavy pressure to the radiator fins of the unit Operate the unit with air filter in place...

Страница 4: ...ackaging Normal Sounds PACKAGING INSERTS Normal Sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Unit may vibrate and make noise because of poor wall or window construction or incorrect installation Vibration Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds So...

Страница 5: ...l setting Higher cool settings will provide lower room temperature Rotate the temperature selector counter clockwise for lower cool settings Lower cool settings will provide higher room temperature Temperature Selector Cool Mode The desired cool setting is selected by rotating the MODE knob to the appropriate location high cool has maximum cooling effect and airflow low cool has minimum cooling ef...

Страница 6: ...cleaning to prevent shock or fire hazards Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Remove filter by sliding out from the right side Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shak...

Страница 7: ...et selector to FAN Temperature selector set too cold for night time cooling To defrost the coil set selector to a FAN position Then set temperature selector to warmer position Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature selector set too warm Turn temperature selector clockwise to a colder setting Air directional louvers positioned improperly Posi...

Страница 8: ...S WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servic...

Отзывы: