READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating.

Plug in &

press RESET

The power supply cord contains a current device that senses damage to the power cord. To test 

your power supply cord do the following:

Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will

notice a click as the RESET button pops out.
Press the RESET button. Again you will notice a click as the button engages.
The power supply cord is now supplying electricity to the unit. (This is also indicated by a light 

on the plug head).

NOTE:

Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,

or it cannot be reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained

from the product manufacturer.

SAFETY PRECAUTIONS

Provide ventilation per installation instructions.

Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.

Do not climb on or place objects on outdoor part of the unit.

Do not hang objects off the unit.

Do not place containers with liquids on the unit.

Turn off the air conditioner at the power source when it will not be used for an extended period of time.

Periodically check the condition of the unit’s installation accessories for any damage.

Do not apply heavy pressure to the radiator fins of the unit.

Operate the unit with air filter in place.

Do not block or cover the intake grille, discharge area and outlet ports.

Ensure that any electrical/electronic equipment is one yard away from the unit.

Do not use or store flammable gases near the unit. 

Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.

Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.

When cleaning the unit, first make sure that the power and circuit breaker are turned off.

CAUTION!  Avoid Injury or damage to the unit or other property 

Содержание FFRA 11 1 Series

Страница 1: ... 265 8352 All about the Use Care of your Room Air Conditioner Care and Cleaning 6 Energy Saving Ideas 6 Before You Call 7 Major Appliance Limited Warranty 8 Product Registration 4 4 Normal Sounds Operating Instructions Packaging 4 5 Important Safety Instructions 2 3 66129926559 June 2009 ...

Страница 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Страница 3: ... It MUST be replaced by one obtained from the product manufacturer SAFETY PRECAUTIONS Provide ventilation per installation instructions Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively Do not climb on or place objects on outdoor part of the unit Do not hang objects off the unit Do not place containers with liquids on the ...

Страница 4: ...truction or incorrect installation Vibration Product Registration Product Registration Packaging Normal Sounds 4 All rights reserved 2009 Electrolux Home Products Inc Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Note Don t try to drill any holes on the base pan to eliminate the normal sounds otherwise it will void the warranty...

Страница 5: ...ilure to follow these instructions may be harmful to your unit Cool Mode The desired cool setting is selected by rotating the MODE knob to the appropriate location hi cool has maximum cooling effect and airflow lo cool has minimum cooling effect and airflow This is used to set the desired room temperature when the unit is being operated in the COOL MODE To set the desired room temperature rotate t...

Страница 6: ...cleaning to prevent shock or fire hazards Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess ...

Страница 7: ...Temperature selector set too cold for night time cooling To defrost the coil set selector to a FAN position Then set temperature selector to warmer position Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature selector set too warm Turn temperature selector clockwise to a colder setting Air directional louvers positioned improperly Position louvers for be...

Страница 8: ...WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Service ...