background image

4

Important Safety
Instructions

                   

              

The  power  supply cord with 

this   air   conditioner   contains  a   current 
detection  device  designed to  reduce  the 
risk of fire.
Please  refer to  the  section ‘Operation  of
Current Device’ for details.
In the event that the  power  supply cord  is 
damaged, it cannot be  repaired it  must be 
replaced   with  a  cord  from   the   Product 
Manufacturer.

Energy Saving Ideas

Read all instructions before using this air conditioner.

                             

For Your Safety

                              

Do  not  store  or  use  gasoline or other flammable vapors and liquids in 
the  vicinity of   this  or  any  other  appliance.  Read  product  labels  for 
flammability and other warnings.

                             

Prevent Accidents

  

To  reduce  the  risk  of  fire,  electrical  shock, or injury to persons when 
using   your   air  conditioner,  follow  basic  precautions,   including  the 
following:

Be  sure  the  electrical  service  is  adequate  for  the  model you have 

    chosen.  This  information  can be  found  on the  serial plate, which is 
    located on the side of the cabinet and behind the grille.

If  the air conditioner is to be  installed in a  window, you  will  probably 

   want to clean both sides of the glass first. If the window is a triple-track 
    type  with  a  screen  panel  included,  remove  the  screen completely 
    before installation.

Be  sure  the  air conditioner has been securely and correctly installed 

    according  to the separate  installation instructions provided with this 
    manual.  Save  this   manual   and   the   installation   instructions   for 
    possible  future use in removing or reinstalling this unit.

When handling the air conditioner, be careful to avoid cuts from sharp 

    metal fins on front and rear coils.

                              

Electrical Information

 

The complete electrical rating of your new room air conditioner is stated 
on  the  serial  plate.  Refer  to  the  rating  when  checking the  electrical 
requirements.

Be  sure  the  air  conditioner is properly grounded. To minimize shock 

    and  fire  hazards,  proper  grounding  is  important. The power cord is 
    equipped  with  a three-prong  grounding  plug  and  a current leakage 
    detection device for protection against shock & firehazards.

Your  air   conditioner  must  be   used  in  a   properly   grounded   wall 

    receptacle. If  the wall  receptacle you intend to use is not adequately 
    grounded  or protected  by a time delay fuse or circuit breaker, have a 
    qualified electrician install the proper receptacle.

Do not run air  conditioner with  outside protective cover in place. This 

    could result in mechanical damage within the air conditioner.

Do not use an extension cord or an adapter plug.

 

Do not  block  inside air  flow with  blinds, curtains or  furniture; or 

    outside with shrubs, enclosures, or other buildings.

The  capacity  of  the  room  air  conditioner  must  fit  the  room size  for 

    efficient and satisfactory operation.

Install   the  room  air  conditioner  on  the  shady  side of your  home.  A 

    window that faces north is best because  it  is  shaded  most of  the day.

Close  the  fireplace  damper,  floor and wall registers  so cool air  does 

    not escape up the chimney and into the duct work.

Keep  blinds  and  drapes  in other  windows closed during the sunniest 

    part of the day.

Clean the air filter as recommended in the section “Care and Cleaning”
Proper  insulation  and  weather stripping in  your  home  will  help keep 

    warm air out and cool air in.

External house shading with trees, plants or  awnings  will help  reduce 

    the air conditioner work load.

Operate  heat  producing  appliances  such as ranges, washers, dryers 

    and dishwashers during the coolest part of the day.

WARNING

WARNING

!

WARNING

WARNING

!

NOTE

NOTE

!

Do   not,   under   any
circumstances,    cut,
remove, or bypass 
the grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Grounding type wall
receptacle

WARNING

WARNING

!

                               Avoid     fire   hazard    or 
electric  shock.  Do  not use  an  extension 
cord or  an  adaptor  plug.  Do  not  remove 
any  prong  from  the  power  cord.

WARNING

WARNING

!

N

E E

 

R

E

G

V

A

Y

S

S

 

Y

A

 

 

E

V

 

 

N

E

 

 

 

O

  M

Содержание FAS255P2A - Heavy Duty Room Air Conditioner

Страница 1: ...NUAL THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CONTROLS P N819042060 01 ...

Страница 2: ...nish after installation This warranty does not cover the following 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY Note Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you 2 Service calls which do not in...

Страница 3: ...t passing through the evaporator during normal operation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Pinging or Swishing Droplets of water hitting the condenser during normal operation may cause pinging or swishing sounds V...

Страница 4: ...d To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug and a current leakage detection device for protection against shock firehazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breake...

Страница 5: ...EST button is pushed or it cannot be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the sym...

Страница 6: ... On Off Sleep Sleep Check Filter Check Filter Remote Sensing Timer Timer Air Conditioner Features continued NOTE The following instructions represent the Control Panel the same instructions can be used for the Remote Control TO TURN UNIT ON YOU WILL SEE DO THIS PRESS ON OFF PAD TO CHANGE TEMPERATURE SETTING YOU WILL SEE DO THIS PRESS TO RAISE PRESS TO LOWER NOTE Tap or hold either up or down butto...

Страница 7: ...Faster Fan Faster On Off On Off Sleep Sleep Check Filter Check Filter Remote Sensing Timer Timer Air Conditioner Features continued TO USE AUTO COOL FEATURE YOU WILL SEE DO THIS PRESS AUTO COOL TO OPERATE ON FAN ONLY YOU WILL SEE DO THIS PRESS MODE BUTTON CHOOSE FAN NOTE Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air Remember to open ven...

Страница 8: ...MODE program can be cancelled at any time during operation by again pressing the Sleep button CHECK FILTER FEATURE YOU WILL SEE NOTE This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check NOTE For Delay Stop the unit must be in the ON position...

Страница 9: ...ster On Off On Off Sleep Sleep Check Filter Check Filter Remote Sensing Timer Timer CLEAN AIR FEATURE on some models YOU WILL SEE NOTE When this feature is ON the electronic air purifier is energized to remove pollen and impurities from the air To cancel this feature press the Clean Air button the LIGHT will turn off NOTE This feature can be activated on the unit control panel ONLY DO THIS PRESS C...

Страница 10: ... Auto Cool Clean Air Clean Air Cool Energy Saver Fan Heat Mode Mode Temp Timer Temp Timer Temp Timer Temp Timer Fan Slower Fan Slower Fan Faster Fan Faster On Off On Off Sleep Sleep Check Filter Check Filter Remote Sensing Timer Timer AUTO AUTO Auto Cool Auto Cool Clean Air Clean Air Cool Energy Saver Fan Heat Mode Mode Temp Timer Temp Timer Temp Timer Temp Timer Fan Slower Fan Slower Fan Faster F...

Страница 11: ...an Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaner wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping aroun...

Страница 12: ...sor to restart when set in the COOL mode Vent set at OPEN position Set vent at CLOSED position for maximum cooling Air direction louvers positioned improperly Position louvers for better air distribution Front of unit is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registers etc open cold air escapes Close doors windows registers e...

Отзывы: