Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not 

the result of defective workmanship or materials in this appliance.

OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this 

occurs. Empty bucket and return bucket to position. 

The dryness level you selected has been reached. Dehumidifier automatically shuts off when selected 

amount of moisture has been removed from the air. If you want to remove more moisture, Select 

'CONTINUOUS' by using the humidity button or knob. After the dehumidifier starts, reset the control 

to the desired setting.
Bucket not installed properly. See “Removing Collected Water“.

Dehumidifier is not turned on. Turn unit on. 
“BUCKET FULL“ light is on. Remove bucket, empty water and re-install correctly.

DEHUMIDIFIER DOES NOT 

OPERATE.

DEHUMIDIFIER IS OPERATING 

BUT ROOM IS NOT DRY ENOUGH. 

Humidity setting is too high. Press the HUMIDITY button or rotate knob to a lower setting or choose 

CONTINUOUS for maximum dryness.

Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the 

longer it takes for the room air to become dry.

Dehumidifier does not have sufficient clearance to operate. Air flow to front grill is blocked. See 

“Selecting a Location“.
Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below 

41 °F(5 °C). See “Operating Conditions“.
Refer to causes under DEHUMlDIFIER RUNS TOO MUCH.

FROST APPEARS ON COILS ABOVE

BUCKET.

Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the coil. 

Frost will usually disappear within 60 minutes.

Room Temperature is too low. All models will operate satisfactorily at temperatures greater than 

41 °F (5 °C). 

FAN NOISE.

Air is moving through the dehumidifier. This is a normal sound.

If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service.

Before You Call

9

2009 Electrolux Home Products, Inc.

All rights reserved.

DEHUMIDIFIER RUNS TOO MUCH.

Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of vacuum 

cleaner to clean grill. See “Care and Cleaning“. Dehumidifier must be placed in a space that does 

not restrict air flowing into the rear coil or out of the front grill.

O

Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the longer 

the dehumidifier will operate.

Windows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside.

Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate.

Dehumidifier is in the CONTINUOUS mode and will remain on in this mode, use the humidity button or 

knob to set a RH% higher level.

Содержание FAD504DWD

Страница 1: ...65 8352 All about the Use Care of your Dehumidifier 49 9 3 3 3 3 June 2009 Loc cati ation 3 3 How It Wo Works 3 3 Im Important Safety Inst struc r tio tions ns s 2 Care And Cleaning 8 Storage Bef Bef B ore ore You Call 9 Maj Maj M or or App Applia liance ce nce Li Limit mi ed Warranty 10 8 8 4 8 8 Operating Instr structions ...

Страница 2: ...ways grip the plug firmly and pull straight out from the receptacle Electrical Information Do not pinch bend or knot the power cord OTE NO SA DANGER Avoid Serious Injury or Death AFETY PRECAUTIONS SA Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups Do not climb on or place objects on the unit Do not hang objects off the unit Do not place containers wi...

Страница 3: ...ls condense or draw moisture from the air and air flows through the top louvers into the room as dry warm air Moisture removed from air is collected in a bucket on the front of the dehumidifier When the unit is started the fan begins to pull moisture laden air across the dehumidifying coils The Compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly...

Страница 4: ...T FULL light is on remove the bucket and re install to reset the float switch NOTE Unit must be upright for one hour prior to operating NOTE 2 To turn the unit on press the ON OFF button The unit will run in the factory setting of CONTINUOUS and high fan speed In the CONTINUOUS mode the unit will only display CO and not the room humidity It is recommended you leave the unit running in the CONTINUO...

Страница 5: ...e you want to return to the CONTINUOUS Mode pressing the HUMIDITY button will lower the Relative Humidity through the 5 increments until the display reads CO 6 The TIMER function enables you to either Delay Start or Delay Stop the unit in the choice from 0 5 hour to 24 hours If the unit is running then selecting Timer will turn the unit off in the hours that will be set Delay Stop If the unit is o...

Страница 6: ...Codes 1 If the display reads AS or ES a sensor has failed Contact your Authorized Frigidaire Service Center 2 If the display reads EC check the following operating conditions Outlet voltage should be 115V 10 and the surrounding temperature should be with in the range of 41 F to 96 F Unplug the unit and plug it in again under normal operating conditions If the EC code persists contact your Authoriz...

Страница 7: ... Remove the bucket as shown in the photographs below and empty the bucket e Replace the empty bucket back into the unit and once seated correctly the unit will start up again f You should hear a click when the bucket is in the correct position Discard water from bucket Water is not potable and cannot be used for drinking WARNING If the bucket full light does not extinguish check that the float is ...

Страница 8: ...e and a drain nearby to discharge the water into b Unscrew the drain cap on the back side of the unit fig 1 c Insert the female threaded end of the hose onto the drain connector of the unit fig 2 d Screw the garden hose onto the threaded portion of the drain connector fig 3 e Make sure the hose is secure so there are no leaks f Direct the hose toward the drain making sure that there are no kinks t...

Страница 9: ...air to become dry Dehumidifier does not have sufficient clearance to operate Air flow to front grill is blocked See Selecting a Location Room temperature is too low Unit will not operate satisfactorily if the room temperature is below 41 F 5 C See Operating Conditions Refer to causes under DEHUMlDIFIER RUNS TOO MUCH FROST APPEARS ON COILS ABOVE BUCKET Dehumidifier has been turned on recently This ...

Страница 10: ...IS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servi...

Отзывы: