Care and Cleaning

1.  Filter

a.  Remove the filter every two weeks based on normal operating conditions.

b.  To remove the filter, remove Bucket then pull filter downwards.

c.  Wash the filter with clean water then dry.

d.  Re-install the filter, then replace Bucket.

2.  Cabinet

a.  Dust cabinet with an oil-free cloth, or using a damp cloth.

b.  Vacuum grill using brush attachment.

3.  Water Bucket

a.  Clean bucket with warm water and detergent.

Storage

When unit is not in use, unplug and use the cord wrap shown for your model type.

25 or 30 Pint Dehumidifier:

50 or 70 Pint Dehumidifier:

2.  Continuous Drainage:

Removing Collected Water

(continued)

a.  For continuous drainage operation, you will need a garden hose and a drain nearby to discharge the water into.

b.  Unscrew the drain cap on the back side of the unit. (fig.1)

c.  Insert the female threaded end of the hose onto the drain connector of the unit. (fig.2)

d.  Screw the garden hose onto the threaded portion of the drain connector. (fig.3)

e.  Make sure the hose is secure so there are no leaks.

f.   Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing.

g.  Place the end of the hose into the drain. (fig.4)

h.  Select the desired humidity setting and fan speed on the unit for continuous draining to start. 

fig. 2

fig. 3

fig. 4

fig. 1

1. Check the seal between the hose and the drain connector. If there is a small leak then replace the hose gasket and re-tighten 

    the hose. 

2. It is recommended that a Dehumidifier Drain Hose - 1/2" (12.7 mm) or larger be used. Make sure there are no 

    kinks or elevations in the hose. 

3. If the mode of continuous drainage is not chosen, the drain cap must be screwed securely to prevent leakage.    

NOTE:

 

Содержание FAD301NWDE0

Страница 1: ...800 265 8352 2 All about the Use Care of your Dehumidifier 1098 Ju Ju u u ne 2 n 009 Loc Location 3 How It It Wo W rks 3 3 Imp Im ortant Safety Inst truc ructio tio tions ns n 2 Care And Cleaning 6 6 Storage Before You Call 7 7 Maj Major o App Applia l nce Limited Warranty 8 8 6 6 4 6 4 6 Operating In I structions ...

Страница 2: ...ways grip the plug firmly and pull straight out from the receptacle Electrical Information Do not pinch bend or knot the power cord OTE NO SA AFETY PRECAUTIONS SA Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups Do not climb on or place objects on the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the d...

Страница 3: ...ls condense or draw moisture from the air and air flows through the top louvers into the room as dry warm air Moisture removed from air is collected in a bucket on the front of the dehumidifier When the unit is started the fan begins to pull moisture laden air across the dehumidifying coils The Compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly...

Страница 4: ...sired point on the dial so the room is kept at a comfortable concentration The unit will cycle on and off keeping the desired level of comfort Operating Instructions Operating Instructions Unit must be upright for one hour prior to operating NOTE N If the BUCKET FULL light is on remove the bucket and re install to reset the float switch If the POWER light blinks every 3 seconds check the following...

Страница 5: ...his time otherwise water may spill on the floor c Press sides of bucket gently to unclip the bucket from the unit d Remove the bucket as shown in the photographs below and empty the bucket e Replace the empty bucket back into the unit and once seated correctly the unit will start up again f You should hear a click when the bucket is in the correct position Discard water from bucket Water is not po...

Страница 6: ...e and a drain nearby to discharge the water into b Unscrew the drain cap on the back side of the unit fig 1 c Insert the female threaded end of the hose onto the drain connector of the unit fig 2 d Screw the garden hose onto the threaded portion of the drain connector fig 3 e Make sure the hose is secure so there are no leaks f Direct the hose toward the drain making sure that there are no kinks t...

Страница 7: ...operate satisfactorily if the room temperature is below 41 F 5 C See Operating Conditions Refer to causes under DEHUMlDIFIER RUNS TOO MUCH FROST APPEARS ON COILS ABOVE BUCKET OR DRIP TRAY Dehumidifier has been turned on recently This is normal due to refrigerant rushing through the coil Frost will usually disappear within 60 minutes Room Temperature is too low All models will operate satisfactoril...

Страница 8: ...S WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servic...

Отзывы: