background image

11

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new.

Be sure to unplug

the unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is necessary.
Trapped particles in the filter can build up and cause an accumulation of frost on
the cooling coils.
• Push the vent handle to the OFF position.
• Tilt the Horizontal Louvers in the UP position, before pulling the filter out.
• Grasp the filter by the center and pull up and out.
• On some models, first tilt the panel out by grasping the panel from both sides

just below the air directional louvers and gently pull to release. Gently pivot the
panel on its hinge, and remove the filter.

• Wash the filter using liquid dishwashing detergent and warm water. Rinse filter

thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly
dry before replacing.

• Or, instead of washing you may vacuum the filter clean.

Cabinet Cleaning

• Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and

front may be dusted with an oil-free cloth or washed with a cloth dampened in a
solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and
wipe dry.

• Never use harsh cleaners, wax or polish on the cabinet front.
• Be sure to wring excess water from the cloth before wiping around the controls.

Excess water in or around the controls may cause damage to the air conditioner.

• The cabinet front can be removed for more thorough cleaning. Refer to “Front

Installation” in this manual.

• Clean the front in a sink using liquid dishwashing detergent and warm water. Rinse

thoroughly and dry.

• Replace cabinet front. Replace the screws.
• Replace front panel (if applicable) and filter. Plug in air conditioner.

Winter Storage

If you plan to store the air conditioner during the winter, remove it carefully from the
window according to the installation instructions. Cover it with plastic or return it to the
original carton.
HINT: Operate unit on "FAN ONLY" for 1 hour before removing unit to dry out
condensate (water) in pan.

NOTE: To prevent rust or electrical connections from being damaged, store air
conditioner in an upright position and a dry place. 

A winter cover can be

purchased from your dealer. The cover will protect the air conditioner when it is left in
place through the winter.

Air Conditioner Feature s

(continued)

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has one of the
louver types described below.

4-Way Louvers

The 4-Way air directional louvers allow you to direct air flow up or down, left or
right throughout the room as needed. To adjust the air directional louvers side-to-
side, use the center handle as you move it side-to-side.

(4-WAY)

Содержание FAC105L1A2

Страница 1: ...OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ELECTRONIC CONTROL P N 309000825 10 99 ...

Страница 2: ... to a grounded power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent...

Страница 3: ...ioner Features 11 Care and Cleaning 12 Avoid Service Checklist 1996 White Consolidated Industries Inc All rights reserved NOTE This Owner s Guide provides specific operating instructions for your model Use the room air conditioner only as instructed in this Owner s Guide These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be...

Страница 4: ...against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This could result in mechanical damage within the air condi...

Страница 5: ...ditioner included in a decorative kit To assemble follow these steps Before installation remove the tilt panel from the frame Grasping the panel from both sides gently pull to release then lift panel from pivot points at bottom of frame STEP 1 INSTALL DECORATIVE FRONT TO CABINET Decorative Front Loosen the screw to the left of the Electronic Control by 1 2 turn to easily install the decorative fro...

Страница 6: ...ze yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote Slip battery cover off and pull the piece of plastic from between the battery end and the connector For some applications the batteries supplied will first need to be installed Note Remember that ...

Страница 7: ...eds will readjust back to LO as the room returns to the original set temperature 7 Note Tap or hold either up or down v button until the desired temperature is seen on the screen This temperature will be automatically maintained anywhere between 60F 15C and 90F 32C If you want the display to read the actual room temperature see step 5 Air Conditioner Features continued DO THIS PRESS TO RAISE PRESS...

Страница 8: ...t running PRESS FAN ONLY CHOOSE ONE DO THIS PRESS ENERGY SAVER YOU WILL SEE STEP 6 TO USE THE ENERGY SAVER FEATURE Note In this mode when the compressor shuts off the fan will continue to run for another 3 minutes then shut off until cooling is needed as sensed by the room temperature control During this time it may come on for 3 minutes to sense whether cooling is needed then it will go off for 1...

Страница 9: ... Up or Down arrows until the desired temperature is indicated on the display Press Timer pad again to show remaining time Switching unit on at any time will nullify this setting DO THIS PRESS if unit is not running PRESS YOU WILL SEE STEP 9 TO SET FOR DELAYED STOP Note The unit must be running to make this setting Proceed as in step 8 to change the desired number of hours The display will then con...

Страница 10: ...ture within 2 3 degrees Fahrenheit between 60F and 90F degrees Fresh Air Vent Control The Fresh Air Vent allows the air conditioner to recirculate inside air OFF draw air into the room FRESH AIR or exhaust stale air to the outside VENT See Figures 1 2 3 for this operation The OFF position is used when MAXIMUM cooling is desired It may also be for room air re circulation without cooling when the se...

Страница 11: ...olish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner The cabinet front can be removed for more thorough cleaning Refer to Front Installation in this manual Clean the front in a sink using liquid dishwashing detergent and warm water Rinse thoroughly and dry Replace cab...

Страница 12: ...Temperature set too cold for night time cooling To defrost the coil set selector to a FAN position Then set temperature warmer Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too high Set temperature lower Vent set at OPEN position Set vent at C...

Отзывы: