Frigidaire FAA086P7A - 8,000 BTU Mini Compact Room Air Conditioner Скачать руководство пользователя страница 7

7

Auto

Temp

Auto

Temp

Auto

Temp

Auto

Temp

TO OPERATE ON FAN ONLY:

DO THIS:

PRESS MODE

BUTTON

CHOOSE FAN

ONLY

Note: 

Use this function only when cooling is not desired, such

as for room air circulation or to exhaust stale air. (Remember
to open the vent during this function, but keep it closed during
cooling for maximum cooling efficiency.) You can choose any
fan speed you prefer.

During this function, the display will show the actual room tem-
perature, not the set temperature as in the cooling mode.

TO USE THE ENERGY SAVER
FEATURE:

DO THIS:

PRESS MODE

BUTTON

CHOOSE

ENERGY SAVER

Note:

 In this mode, the fan will continue to run for 3 minutes

after the compressor shuts off. The fan then cycles on for 2
minutes at 10 minute intervals until the room temperature is
above the set temperature, at which time the compressor turns
back on and cooling stars.

YOU WILL SEE:

YOU WILL SEE:

Air Conditioner Features

(continued)

LIGHT On

LIGHT On

Auto

Temp

Auto

Temp

TIMER: DELAY STOP / START

FEATURE

DO THIS:

PRESS

TIMER BUTTON

YOU WILL SEE: TIMER SETTING

LIGHT On

Note: For Delay Stop, the unit must be in the On position.

Note: For Delay Start, the unit must be in the Off position.

To adjust timer setting, tap or hold the UP arrow( 

 ) or the DOWN

arrow( 

 ) to change delay timer at .5 hour increments, up to 10

hours, then at 1 hour increments up to 24 hours. The control will count
down the time remaining until start (8, 7.5, 7, etc.). The Delay Start
mode automatically selects cooling with maximum Fan Speed. The
temperature maintained will be the same as previously set. To change
the set temperature, press “COOL” then Up or Down arrows until the
desired temperature is indicated on the display. After 5 seconds, the
control will automatically change the display back to the hours re-
maining until the unit will start/stop. Turning the unit “ON” or “OFF” at
any time will cancel the Delay Start/Stop function.
The Delay Start/Stop Feature will work until the unit either starts or
stops. Once that happens the above steps have to be repeated again.

SZ000705(En)-YaoKong

09/2/2005, 2:20 PM

7

Содержание FAA086P7A - 8,000 BTU Mini Compact Room Air Conditioner

Страница 1: ...USE CARE MANUAL ELECTRONIC CONTROL AIR CONDITIONER READ AND SAVE THESE INSTRUCTIONS P N 220201d052 SZ000705 En YaoKong 09 2 2005 2 20 PM 1 ...

Страница 2: ... house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES ...

Страница 3: ...Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal o...

Страница 4: ... is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with out...

Страница 5: ...ON ACTIVATES REMOTE THERMOSTAT SETS MODES Auto Temp LIGHT ON OFF REMOTE CONTROL ACTIVATES TIMER FAN SPEEDS SETS MODES ADJUSTS TEMP TIMES Auto Temp Auto Temp DISPLAYS TEMPERATURE TIME FAN SPEED ADJUSTS TEMPERATURE OR TIME ACTIVATES TIMER CHECK FILTER RESET BUTTON SETS MODE CLEAN AIR FEATURE some models TURNS UNIT ON OR OFF REMOTE TEMP SENSING INDICATOR SOME MODELS AUTO TEMP FEATURE SLEEP MODE SETS ...

Страница 6: ...Note Tap or hold either up or down button until the desired temperature is seen on the display This tempera ture will be automatically maintained anywhere between 60 F 16 C and 90 F 32 C If you want the display to read the actual room temperature See To Operate on Fan Only sec tion on Page 7 TO USE AUTO TEMP FEATURE YOU WILL SEE DO THIS PRESS AUTO TEMP Note Fan starts at High Speed and adjusts to ...

Страница 7: ...HT On Auto Temp Auto Temp TIMER DELAY STOP START FEATURE DO THIS PRESS TIMER BUTTON YOU WILL SEE TIMER SETTING LIGHT On Note For Delay Stop the unit must be in the On position Note For Delay Start the unit must be in the Off position To adjust timer setting tap or hold the UP arrow or the DOWN arrow to change delay timer at 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours ...

Страница 8: ...ESS SLEEP BUTTON YOU WILL SEE SLEEP FEATURE LIGHT On Auto Temp Auto Temp CHECK FILTER FEATURE YOU WILL SEE LIGHT On CLEAN AIR FEATURE on some models LIGHT On YOU WILL SEE DO THIS PRESS CLEAN AIR BUTTON Note This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filt...

Страница 9: ...ignal The LIGHT on the remote control will pulse each time it sends a signal It will continue to send this signal until the feature is deactivated by pressing the remote sensing button If the unit does not receive the remote sensing signal during any 3 minute interval the unit will beep to indicate the remote sensing mode has ended The display on the remote control indicates the temperature at the...

Страница 10: ...of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other and back press and hold the TEMP TIMER Up and Down buttons together for 3 seconds The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run duri...

Страница 11: ...rols Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Energy Saving Ideas Do not block air flow inside with blinds cu...

Страница 12: ...NLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air distribution Front of unit is blo...