Freestanding Range Specifications

 Product Shipping Weight (approx.) – 230 Lbs.

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz, 

fused on both sides of line with ground.

 Connected Load (kW Rating) @ 240 / 208 Volts = 15.0 / 11.5 kW

 Recommended Circuit Breaker – 40 Amps 

 Always consult local and national electric codes.

 Make sure wall coverings around range can withstand heat generated 

by range.

 Floor beneath range MUST be solid and level.

 Overhead cabinetry should not exceed a 13" maximum depth.

 Absolute minimum horizontal distance between overhead cabinets 

installed to either side of appliance must be no less than maximum 

width of appliance.

 Range can be installed flush to wall with 0" minimum rear clearance.

 Minimum 1" clearance required from edge of rangetop to nearest 

combustible wall on either side of range above 36" height.

 Allow 30" minimum clearance between top of cooking surface and 

bottom of unprotected wood or metal overhead cabinet; or 24" 

minimum clearance when bottom of wood or metal overhead cabinet 

is protected by not less than 1/4" flame retardant millboard covered 

with not less than No. 28 MSG sheet steel, 0.015" stainless steel, 

0.024" aluminum or 0.020" copper. 

 To reduce risk of fire when using overhead cabinetry, install 

range hood that projects horizontally a recommended minimum  

of 5" beyond bottom of cabinets.

 Follow all dimension requirements provided to prevent property 

damage, potential fire hazard, and incorrect countertop and  

cabinet cuts.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.ca for detailed instructions.

30" Full Induction / Induction Hybrid Freestanding Ranges