background image

7

ELECTRICAL INSTALLATION

ELECTRIC Dryer

 The following are specific requirements for proper and

safe electrical installation of your dryer. Failure to follow these
instructions can create electrical shock and/or a fire hazard.

 

This appliance MUST be properly grounded.

 Electrical

shock and /or fire can result if the dryer is not properly grounded. Follow the
instructions in this manual for proper grounding.

 

Do not use an extension cord with this dryer.

 Some

extension cords are not designed to withstand the amounts of electrical
current this dryer utilizes and can melt, creating electrical shock and/or fire
hazard. Locate the dryer within reach of the receptacle for the length
power cord to be purchased, allowing some slack in the cord. Refer to the
pre-installation requirements in this manual for the proper power cord to be
purchased.

 

A U.L. approved strain relief must be installed onto power

cord. 

If the strain relief is not attached, the cord can be pulled out of the

dryer and can be cut by any movement of the cord, resulting in electrical
shock.

 

Do not use an aluminum wired receptacle with a copper

wired power cord and plug (or vice versa).

 A chemical reaction occurs

between copper and aluminum and can cause electrical shorts. 

The proper

wiring and receptacle is a copper wired power cord with a copper
wired receptacle.
NOTE:

 Dryers operating on 208 volt power supply will have longer

drying times than operating on 240 volt power supply.

GROUNDING REQUIREMENTS

NON-CANADIAN ELECTRIC Dryer

 Improper connection of the equipment grounding conductor

can result in a risk of electrical shock. Check with a licensed electrician if you
are in doubt as to whether the appliance is properly grounded.

For a grounded, cord-connected dryer:

1. The dryer 

MUST

 be grounded. In the event of a malfunction or

breakdown, grounding will reduce the risk of electrical shock by a path
of least resistance for electrical current.

2. If your dryer is equipped with a power supply cord having an equipment-

grounding conductor and a grounding plug, the plug 

MUST

 be plugged

into an appropriate, copper wired receptacle that is properly installed
and grounded in accordance with all local codes and ordinances. If in
doubt, call a licensed electrician.

  Do not modify plug provided with

the appliance.

For a permanently connected dryer:

1. The dryer 

MUST

 be connected to a grounded metal, permanent wiring

system; or an equipment grounding conductor must be run with the
circuit conductors and connected to the equipment-grounding terminal
or lead on the appliance.

Canadian  ELECTRIC Dryer

DANGER

 Improper connection of the equipment grounding conductor

can result in a risk of electrical shock. Check with a licensed electrician if you
are in doubt as to whether the appliance is properly grounded.

For a grounded, cord-connected dryer:
1. The dryer must be grounded. In the event of a malfunction or breakdown,

grounding will reduce the risk of electrical shock by a path of least
resistance for electrical current.

2. Since your dryer is equipped with a power supply cord having an

equipment-grounding conductor and a grounding plug, the plug must
be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances. If in doubt,
call a licensed electrician.  

Do not modify plug provided with the

appliance.

ALL GAS Dryers

This dryer is equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding prong from this
plug.

ELECTRICAL CONNECTIONSFOR 3-WIRE SYSTEM

NON-CANADIAN  ELECTRIC Dryer

1. Remove the screws securing the terminal block access cover and the

strain relief mounting bracket located on the back of the dryer upper
corner.

2. Install a U.L. approved strain relief into the power cord entry hole of the

mounting bracket. Finger tighten the nut only at this time.

3. Thread a U.L. approved 30 amp. power cord, NEMA 10-30 type SRDT,

through the strain relief.

4. Attach the power cord neutral (center wire) conductor to the silver

colored center terminal on the terminal block. Tighten the screw securely.

5. Attach the remaining two power cord outer conductors to the outer

brass colored terminals on the terminal block. Tighten both screws
securely.

 Do not make a sharp bend or crimp wiring/ conductor

at connections.

6. Reattach the strain relief mounting bracket to the back of the dryer

with two screws. Tighten screws securely.

POWER CORD

TIGHTEN NUT
TO THESE
THREADS

STRAIN
RELIEF
MOUNTING
BRACKET

GREEN
GROUND
SCREW

NUT

NEUTRAL
GROUND
WIRE

SILVER
TERMINAL

7. Tighten the screws securing the cord restraint firmly against the power

cord.

8. Tighten the strain relief nut securely so the strain relief does not turn.

9. Reinstall the terminal block cover.

Содержание AEQ7000ES

Страница 1: ...TA La alimentación eléctrica para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Eléctrico Nacional ANSI NFPA 70 NOTA La alimentación de gas para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Nacional para Gases Combustibles ANSI Z223 1 NOTA La secadora está clasificada para USO DOMESTICO sol...

Страница 2: ...tacle to be located so the power supply cord is accessible when the dryer is in the installed position Canada NEMA 14 30R receptacle NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in...

Страница 3: ...column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is acceptable certain extenuating circumstances could affect the performance of the dryer Only the rigid metal d...

Страница 4: ...1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 27 68 58 5 13 97 29 75 57 13 34 29 5 12 70 2 6 03 3 8 34 86 36 35 88 90 2 25 5 72 Stacked Dryer Installation Dimensions To front of cabinet 28 25 71 76 To clear kobs 28 75 73 03 To clear door 29 5 74 93 To clear open door 53 134 62 13 5 34 29 27 68 58 Ele...

Страница 5: ... MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your dealer 5 R...

Страница 6: ...AL INSTRUCTIONS Be sure to wear gloves while reversing the door assembly You will need a square drive screw driver a Phillips head screwdriver and pliers 1 Open the dryer door 2 Remove the two screws that secure the door hinge to the front panel Remove the bottom screw first Support the door assembly firmly before removing the top screw 3 Hold the door near the top and bottom and lift to remove th...

Страница 7: ... dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if yo...

Страница 8: ...gs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating a...

Страница 9: ...terior de la vivienda y selle todas las juntas con cinta adhesiva para ductos Todos los accesorios de tubería machos DEBEN ser instalados aguas abajo del flujo de aire Riesgo de explosión No instale la secadora donde se guarda gasolina u otros materiales inflamables Si la secadora se instala en un garage ella debe estar por lo menos 18 pulgadas 45 7 cm por encima del suelo El incumplimiento puede ...

Страница 10: ...87 1 cm 387 1 cm 387 1 cm 387 1 cm2 2 2 2 2 REQUERIMIENTOS DEL SUMINISTRO DE GAS Reemplace la tubería de conexión de cobre que no está recubrida con plástico El latón inoxidable o recubrido con plástico DEBE SER utilizado 1 La instalación DEBE hacerse cumplir con los códigos locales o en ausencia de los mismos de acuerdo con los estandares del National Fuel Gas Code Código Nacional para Gases Comb...

Страница 11: ... 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 Al frente del gabinete 28 25 71 76 A las perillas claras 28 75 73 03 A las perillas puerta 29 5 74 93 En ei claro abra la puerta 53 134 62 ...

Страница 12: ... adquirir con su distribuidor 5 Vealaspáginas2y3paraotrosrequísitosimportantesdeventilación 6 La instalación DEBE cumplir con las estándares aplicables de la Manufactured Home Construction Safety Standard Estándares de Seguridad y Construcción de Casas Prefabricadas Título 24 CFR Parte 32 80 del Reglamento Federal o cuando dichos estándares noseanaplicables sedebencomplirconlosestándaresdelaAmeric...

Страница 13: ...uerta los dos tornillos de fijación de la bisagra un tapón cuadrado dos tapones redondos y un percutor de metal 8 Gire la bisagra y vuelva a engancharla a la parte opuesta de la contrapuerta 9 Deseche el viejo percutor de metal e instale uno nuevo incluido en el paquete de documentación en el lado opuesto de la contrapuerta Vuelva a instalar los tapones redondos y el tapón cuadrado en los agujeros...

Страница 14: ...on cables de aluminio con un cordón y un enchufe de cobre o viceversa Se produce una reacción química entre el cobre y el aluminio que puede causar cortacircuitos El cableado y tomacorriente apropiado es un cordón eléctrico equipado con conductores de cobre con un tomacorriente con conductores de cobre NOTA Las secadoras que operan con un suministro de energía de 208 voltios usarán más tiempo de s...

Страница 15: ...cados por el fabricante podía dar lugar a daños corporales a daños materiales o a daño a la secadora Si necesita obtener piezas de recambio para su secadora póngase en contacto con el distribuidor donde compró su secadora llame 1 800 944 9044 o visitan nuestros website www frigidaire com para la Distribuidor Autorizada Company de las Piezas de Frigidaire más cercana usted Cuando se reparan los con...

Отзывы: