Frigidaire AEQ6700FS - 27

6

7.

Remove the two #10-16x.50 hinge attachment screws
and the two #10-16x.50 striker plate attachment
screws.

8.

Rotate the hinge and strike plate and reattach them to
the opposite sides of the inner door.

9.

Remove the hinge cutout plug. Rotate it and install it in
the opposite side of the outer door.

10. Reattach the door assemblies in reverse order.

11. Support the door assembly firmly; insert the hinge “T”

post into the “T” slot in the front panel and lift to align
the screw holes.

12. While supporting the door assembly, install the mount-

ing screws.

13. Close the door.

DRYER DOOR REVERSAL INSTRUCTIONS

Be sure to wear gloves while reversing the door assembly.

1.

Open the dryer door.

2.

 Remove the two #10-16x.50 that secures the door
assembly to the front panel. 

NOTE

: Remove the bottom

screw first. Support the door assembly firmly before
removing the top screw.

3.

Remove the door assembly by lifting and pulling toward
the center of the unit opening.

4.

Place door assembly face down on a soft flat surface.

5.

Remove the two round plugs and one “T” plug from the
front panel. Reinstall them in the position vacated by
the hinge.

6.

Remove the five #10-14x5/8 screws, 1 thru 5 and the
two #10-16x.50 screws, 6 thru 7, that attach the inner
door assembly to the outer door assembly. Lift the inner
door assembly out of the outer door assembly.

Содержание AEQ6700FS - 27" Electric Dryer

Страница 1: ...TA La alimentación eléctrica para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Eléctrico Nacional ANSI NFPA 70 NOTA La alimentación de gas para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Nacional para Gases Combustibles ANSI Z223 1 NOTA La secadora está clasificada para USO DOMESTICO sol...

Страница 2: ...receptacle to be located so the power supply cord is accessible when the dryer is in the installed position NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation When the dryer...

Страница 3: ...column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is acceptable certain extenuating circumstances could affect the performance of the dryer Only the rigid metal d...

Страница 4: ...1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 27 68 58 5 13 97 29 75 57 13 34 29 5 12 70 2 6 03 3 8 34 86 36 35 88 90 2 25 5 72 Stacked Dryer Installation Dimensions To front of cabinet 28 25 71 76 To clear kobs 28 75 73 03 To clear door 29 5 74 93 To clear open door 53 134 62 13 5 34 29 27 68 58 Ele...

Страница 5: ... MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your dealer 5 R...

Страница 6: ...door DRYER DOOR REVERSAL INSTRUCTIONS Be sure to wear gloves while reversing the door assembly 1 Open the dryer door 2 Remove the two 10 16x 50 that secures the door assembly to the front panel NOTE Remove the bottom screw first Support the door assembly firmly before removing the top screw 3 Remove the door assembly by lifting and pulling toward the center of the unit opening 4 Place door assembl...

Страница 7: ... 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are ...

Страница 8: ...gs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating a...

Страница 9: ...os los accesorios de tubería machos DEBEN ser instalados aguas abajo del flujo de aire NOTA No saque por ESPIGA SecadorasaGAS CIRCUITO Circuito individual derivado de 15 amp con fusibles de 15 amp de retardo máximo o disyuntor Utilice circuitos de fusibles separados para la lavadora y la secadora No opere una lavadora y una secadora en el mismo circuito ALIMENTACIÓN ELÉCTRICA Corriente alterna mon...

Страница 10: ...87 1 cm 387 1 cm 387 1 cm 387 1 cm2 2 2 2 2 REQUERIMIENTOS DEL SUMINISTRO DE GAS Reemplace la tubería de conexión de cobre que no está recubrida con plástico El latón inoxidable o recubrido con plástico DEBE SER utilizado 1 La instalación DEBE hacerse cumplir con los códigos locales o en ausencia de los mismos de acuerdo con los estandares del National Fuel Gas Code Código Nacional para Gases Comb...

Страница 11: ... 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 Al frente del gabinete 28 25 71 76 A las perillas claras 28 75 73 03 A las perillas puerta 29 5 74 93 En ei claro abra la puerta 53 134 62 ...

Страница 12: ... adquirir con su distribuidor 5 Vealaspáginas2y3paraotrosrequísitosimportantesdeventilación 6 La instalación DEBE cumplir con las estándares aplicables de la Manufactured Home Construction Safety Standard Estándares de Seguridad y Construcción de Casas Prefabricadas Título 24 CFR Parte 32 80 del Reglamento Federal o cuando dichos estándares noseanaplicables sedebencomplirconlosestándaresdelaAmeric...

Страница 13: ...puerta 1 Abre la puerta de la secadora 2 Retire los dos tornillos No 10 de 16x 50 que aseguran la puerta al panel frontal NOTA Retire primero el tornillo de abajo Sostenga firmemente la puerta antes de retirar el tornillo de arriba 3 Retire la puerta levantándola y tirando hacia el centro de la unidad 4 Coloque la puerta hacia abajo sobre una superficie plana y suave 5 Retire los dos tapones redon...

Страница 14: ...e aluminio con un cordón y un enchufe de cobre o viceversa Se produce una reacción química entre el cobre y el aluminio que puede causar cortacircuitos El cableado y tomacorriente apropiado es un cordón eléctrico equipado con conductores de cobre con un tomacorriente con conductores de cobre NOTA Las secadoras que operan con un suministro de energía de 208 voltios usarán más tiempo de secado que a...

Страница 15: ...cados por el fabricante podía dar lugar a daños corporales a daños materiales o a daño a la secadora Si necesita obtener piezas de recambio para su secadora póngase en contacto con el distribuidor donde compró su secadora llame 1 800 944 9044 o visitan nuestros website www frigidaire com para la Distribuidor Autorizada Company de las Piezas de Frigidaire más cercana usted Cuando se reparan los con...

Отзывы: