Dryer Tech Data Sheet

This information is intended for Qualified Technicians Only. 

CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING

Please Return This Sheet to its Envelope in the Product for Future Reference

READING ERROR CODES

1.  Press and hold the 

Select

and

 Cancel

 buttons simultaneously for 6 seconds to reset control. The buzzer will sound 1 time 

and “

rES

” will be shown briefly in the display. 

2.  Immediately after, rotate cycle selector knob 2 turns counter-clockwise to the third position from the top, and then  
 

press and hold the 

Select

and

Cancel

 buttons simultaneously for 6 seconds. The control will enter Field Test Mode, the  

 

buzzer will sound 3 times, and the digital display will alternate between “

Fld

” and the firmware revision number (ex. “

r03

”). 

3.  Rotate the cycle selector knob 2 turns counterclockwise. The error code will appear in the digit display. 

Troubleshoot problem by using chart below.  
To move on to the next code, press the 

Options

 button. 

To clear code, press the 

Select

 button. Code will be cleared when mode is exited. 

To exit this mode, simultaneously press and hold the

 Select 

and

 Cancel

 buttons for 6 seconds. 

Error Code 

Label 

Description 

Solution 

E10

General EEPROM 
Fault

Problem with communication 
between EEPROM and the 
microprocessor.

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.

E11

Checksum Error  

Problem with communications or 
memory did not check, one has 
become corrupted.  

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.

E12

Non fatal R/W 
error  

Problem reading or writing to the 
memory or input/output.  

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.

E24

Control NTC Short 
Circuit

Control thermistor or its wiring is 
shorted.

Remove wires from control thermistor. Measure resistance of thermistor. If 
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 
10%), check wiring between thermistor and electronic control. If good, 
replace electronic control.

E25

Control NTC Open 
Circuit

Control thermistor or its wiring is 
open.

Remove wires from control thermistor. Measure resistance of thermistor. If 
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 
10%), check wiring between thermistor and electronic control. If good, 
replace electronic control.

E4A

Program Timeout 
Fault

The drying time has exceeded 
program time for that cycle.  

Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. 
Position cycle selector to NORMAL, temperature selector to HIGH HEAT 
and touch START. Check for anything that would extend dry times such as: 
no heat, restricted vent, blower fan blade broken or loose, dryer installed in 
closet with solid door, or bad connection in moisture sensor bar circuit or 
dirty bars. If dryer operates normally but code returns, replace electronic 
control.

E5B

Heater Fault (no 
heating)

Temperature reading of control 
thermistor has not changed in a 
certain amount of time.  

Position cycle selector to NORMAL, temperature selector to HIGH HEAT 
and touch START. Measure voltage across terminals on relay RL2 (heater 
relay) on electronic control. If meter reads 240V on electric models and 
120V on gas models, replace electronic control. If meter reads zero, remove 
power from dryer. Disconnect wire going to NO terminal on the relay RL2. 
Reconnect power and measure voltage drop between terminal COM on 
relay RL2 and neutral. If meter reads zero, wire between incoming line and 
relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.  

E68

Key (button) Struck 
Fault

One of the keys (buttons) is stuck 
closed (active).

Enter function test mode and perform key (button) test to determine which 
button is at fault. Carefully free the and perform the test again. If button is 
free but the key struck code still exists, replace electronic control.  

E8C

Too many trips in a 
period of time.

The safety (high limit) thermostat 
has tripped too many times within 
a certain period of program time.  

Check for blocked lint filter, blocked exhaust, air leaks around air duct, 
broken blower fan blades, worn or loose drum seals, dryer installed in closet 
with solid doors or door seal not correctly seated.  

EAF

Watch Dog Reset  

Microcontroller has been reset by 
internal Watchdog timer.

Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.

NOTE:

 During normal operation, the display may show: 

 

ad

” - dryer is in an auto dry cycle. 

 

dn

” - cycle is done in auto dry. 

 

PF

” - a power failure to the board has occurred. 

 

Err

” - an error has been detected. 

 

LOC

” - control lock is activated. 

 

PAU

” - cycle has been interrupted.

Содержание AEQ6000ES - AffinityTM 5.8 cu. Ft. Dryer

Страница 1: ... thermistor If reading is within 50 K 10 check wiring between thermistor and electronic control If good replace electronic control E4A Program Timeout Fault The drying time has exceeded program time for that cycle Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes Position cycle selector to NORMAL temperature selector to HIGH HEAT and touch START Check for anything that would e...

Страница 2: ...ing moisture sensor readings Opening the door press in on door switch plunger and placing a finger on the both moisture sense bars at the same time will make the numbers decrease In controls that do not have a digit display the More Dry LED should be ON Opening the door press in on door switch plunger and placing a finger on the both moisture sense bars at the same time will make the Damp LED come...

Страница 3: ...as de 50 K 10 remplacez la thermistance Si la lecture est de 50 K 10 vérifiez le câblage entre la thermistance et la commande électronique Si celui ci est bon remplacez la commande électronique E4A Défectuosité de temps d arrêt du programme La durée de séchage a excédé la durée du programme pour ce cycle Appuyez sur les boutons Pause Annuler Pause Cancel et Sélectionner Select durant 6 secondes po...

Страница 4: ...Séchage et Refroidissement sont allumés et les chiffres apparaissent dans l afficheur indiquant les lectures du capteur d humidité En ouvrant la porte appuyer sur l interrupteur à poussoir de porte et en plaçant simultanément un doigt sur les deux barres de captage d humidité les chiffres diminuent Dans les commandes qui ne disposent pas d afficheur numérique le voyant Plus sec More dry devrait êt...

Страница 5: ...ermistor Si la lectura no es 50 K 10 cambie el termistor Si la lectura está dentro de 50 K 10 verifique el cableado entre el termistor y el control electrónico Si está en buen estado cambie el control electrónico E4A Falla del Tiempo de Espera del Programa El tiempo de secado ha excedido el tiempo del programa para ese ciclo Presione los botones Pausa Cancelar y SELECCIONAR durante 6 segundos para...

Страница 6: ...ED de Secado y Enfriado están encendidas y aparecen números en pantalla que muestran las lecturas del sensor de humedad Si se abre la puerta presione sobre el émbolo del interruptor de la puerta y se coloca un dedo sobre ambas barras sensoras de humedad al mismo tiempo esto hará que los números bajen En los controles que no tienen una pantalla digital la luz Más Secado debe estar ENCENDIDA Si se a...

Страница 7: ......

Страница 8: ......

Отзывы: