G

11½”

(29.2 cm)

1¼”

(3.2 cm)

Min.

3” (7.6 cm)

Max.

1” (2.5 cm)

Min.

40-15/16”

(104 cm)

C

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

 FOR YOUR SAFETY:  Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

Your new wall oven has been designed to fit a limited variety of cutout sizes to make the 
job of installing easier. The first step of your installation should be to measure your current 
cutout dimensions and compare them to the cutout dimensions chart below for your 
model. You may find little or no cabinet work is necessary.

 

P/N 318201533 (0904) Rev. A 

English – pages 1-6

Español – páginas 7-12

All dimensions are stated in inches and (cm).

 Do not remove spacers (if equipped) on the side walls and/or on the back of the built-

in oven. These spacers center the oven in the space provided. The oven must be centered to prevent 
excess heat buildup that may result in heat damage or fire.

2" (5 cm) Wide Wood 

Spacer if Needed

NOTES: 
1.

 Base must be capable of supporting 225 pounds (102 kg).

 

2. 

 Allow at least 21" (53.3 cm) clearance in front of oven for door 

depth when it is open.

3. 

Dimension

 G 

(cutout depth)

 

is 

critical to the proper installation 
of the built-in oven.  If the 
oven decorative trim does not 
butt against the cabinet verify 
dimension 

G

 to assure it is the 

required depth.

Door Open
(see note 2)

Spacer

Electrical

Junction Box

(right or left side)

Hole for 
Cable 
(right or 
left side 
depending 
on model)

*  Suggested distance from floor 

is 11½" (29.2 cm).

  Minimum required distance is 

4 ½" (11.4 cm)

Figure 1

Printed in United States

PRODUCT DIMENSIONS

MODEL

A

B

C

D

27" (68.6cm) Wall Oven

27 (68.6)

42¾ (108.6)

24

5

/

8

 (62.5)

24½ (62.2)

30" (76.2cm) Wall Oven

30 (76.2)

42¾ (108.6)

28¼ (71.8)

24½ (62.2)

CUTOUT DIMENSIONS AND CABINET WIDTH

MODEL

F

G. Min.

H

I

Min.

Max.

Min.

Max.

27" (68.6cm) Wall Oven

24

7

/

8

 (63.2)

25¼ (64.1)

23½ (59.7)

41

1

/

8

  (104.5)

41¼ (104.8)

27

1

/

8

 (68.9) Min

30" (76.2cm) Wall Oven

28½ (72.4)

29 (73.7)

23½ (59.7)

41

1

/

8

  (104.5)

41¼ (104.8)

30

1

/

8

 (76.5) Min

Canada

United States

Содержание 318201533

Страница 1: ... These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire 2 5 cm Wide Wood Spacer if Needed NOTES 1 Base must be capable of supporting 225 pounds 102 kg 2 Allow at least 21 53 3 cm clearance in front of oven for door depth when it is open 3 Dimension G cutout depth is critical to the proper installation of t...

Страница 2: ...idual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage Table A Appliance Rating Watts 240V Protection Circuit Recommended Appliance Rating Watts 208V Protection Circuit Recommended Less than 4800W 20A...

Страница 3: ...s manufactured with a white neutral power supply and a frame connected copper wire The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit if used in USA in a new branch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lea...

Страница 4: ...supply 2 Separate the green or bare copper and white appliance cable wires 3 In the junction box connect appliance and power supply cable wires as shown in Figure 4 Figure 4 4 WIRE GROUNDED JUNCTION BOX Cable from Power Supply White Wire Junction Box Cable from appliance White Wire Black Wires Red Wires Ground Wire Ground Wire Bare or Green Wire U L Listed Conduit Connector or CSA listed Figure 5 ...

Страница 5: ... the door is open The anti tip mounting screws supplied with the wall oven must be installed to prevent tipping of the wall oven and injury to persons A The mounting holes in the side trims may be used as a template to locate the appliance mounting screw holes see figure 6 B Use the two screws supplied to fix the appliance to the cabinet 7 Install the Bottom Trim Place the top of the bottom trim o...

Страница 6: ...l for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to your Use and Care Guide for service phone numbers 5 Leveling the Wall Oven 1 Install an oven rack in the center of the upper oven see Figure 8 2 Place a level on t...

Страница 7: ...no debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio Espaciador de Madera de 2 5 cm de ancho si es necesario NOTAS 1 La base debe poder sostener 255 libras 102kg 2 Deje por lo menos 21 53 3 cm de espacio libre para la profundidad de la puerta cuando esta abierta 3 La dimensión G profundidad del corte está primordial para i...

Страница 8: ...stico y conectarse a un circuito individual correctamente puesto a tierra protegido por un interruptor o un fusible Para conocer el interruptor o fusible que requiere su modelo vea la placa serial para encontrar la consumación del vatiaje y refierase al cuadro A para encontrar el amperaje del interruptor o fusible Table A Grados de Vatios del electrodoméstico 240V Se recomienda una protección al c...

Страница 9: ... alambre de cobre conectado al armazón El armazón esta puesto a tierra por un enlace de la conexión a tierra con la conexión del neutro al final de la línea eléctrica si es usado en los estados unidos una nueva instalación de circuito de bifurcación 1996 NEC casa rodante vehículos recreacionales o donde los códigos locales no permitan poner a tierra mediante el neutro blanco o en Canadá desconecta...

Страница 10: ...anco Alambre rojos Alambre negros Alambre blanco Ubicación del número de modelo y de serie La placa con el número de serie está ubicada en la guarnición interior lateral del horno y se puede ver cuando se abre la puerta Cuando haga pedidos de repuestos o solicite información con respecto a su horno esté siempre seguro de incluir el número de modelo y de serie y el número o letra del lote de la pla...

Страница 11: ... guía para localizar los tornillos de montado de la unidad figura 6 B Use los dos tornillos proporcionados para colocar la unidad en la cabina tornillos de montado Figura 6 7 Instalación de la Guarnición Inferior Colocar la parte superior de la guarnición inferior sobre las lengüetas laterales del horno debajo de la puerta del horno y fijarlas usando los 2 tornillos provistos con los orificios de ...

Страница 12: ...nual del Usuario Esto le podrá ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricación de este artefacto Lea la garantía y la información sobre el servicio en su Manual del Usuario para obtener el número de teléfono gratuito y la dirección del servicio 6 Asegúrese de que el horno de pared está a nivel 1 Instale una rejilla al c...

Отзывы: