iCE MAKER iNFORMATiON
Test Cycling
Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
TUR
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Water Fill Volume
The water fill adjustment
screw will change the
fill time. One full turn is
equal to 20cc (.68 oz.).
The correct fill is 102 to
130cc (3.4 to 4.3 oz.).
When a water valve is
replaced, the fill volume
must be checked.
sERViCE dATA shEET - 240389636
R134a
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE MODELS
iMpORTANT sAFETy NOTiCE
The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing.
iMpORTANT
If any green grounding wires are moved during servicing, they
must be returned to their original position and properly se-
cured.
CAuTiON:
All electrical parts and wiring must be
shielded from torch flame. do not allow torch to contact
insulation; it will char at 200°F and flash ignite (burn) at
500°F. Excessive heat will distort the plastic liner.
NOTE:
This product comes equipped with an Electronic
Defrost Control. To initiate defrost, depress the fresh food light
switch 5 times in 6 seconds (light bulb must be working). To
terminate defrost, depress the fresh food light switch 5 times
in 6 seconds.
pERFORMANCE dATA
NO LOAd ANd NO dOOR OpENiNGs AT Mid-pOiNT CONTROL sETTiNG
Type A with Run/Start Capacitor
65ºF (18ºC) Ambient
90ºF (32ºC) Ambient
Operating Time
32 to 40%
55 to 65%
Freezer Temperature
0º to 4ºF
-18º to -16ºC
-1º to 3ºF
-18º to -16ºC
Refrigerator Temperature
34º to 39ºF
1º to 4ºC
34º to 39ºF
1º to 4ºC
Low Side Pressure (cut-in)
5 to 12 psig
34 to 83 kPa
5 to 12 psig
34 to 83 kPa
Low Side Pressure (cut-out)
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure
(Last 1/3 of cycle)
90 to 115 psig
621 to 793 kPa
130 to 155 psig
896 to 1069 kPa
Wattage (Last 1/3 of cycle)
120 to 150
130 to 160
Amps (Running)
1.2 to 1.5
1.2 to 1.5
Base Voltage
115 vac (127 vac max)
115 vac (127 vac max)
dEFROsT spECiFiCATiONs
Cabinet Size
Thermostat
Heater
Cut-In
Cut-Out
Watts
Ohms
23’ & 26’
25ºF
-4ºC
47ºF
8ºC
450
30
Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time
CONdENsER FAN MOTOR
Watts
RPM
Amps
3.1 (Energy Star - Some models)
1100 CW Opposite Shaft
.03 Running
8.0
2550 CW Opposite Shaft
.07 Running
iCE MAKER spECiFiCATiONs
Electrical
115 vac (127 vac max)
60 Hertz
Thermostat
Opens at 48ºF (9ºC)
Closes at 15ºF (-9ºC)
Heater Wattage
165
iCE MAKER pLuG CONNECTiONs
Wire Number
Wire Color
Connect to:
1
Green/Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Lt. Blue
Neutral
POWER
ICE MAKER
IC
E M
AKE
R
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THER MAL
CUT-OUT
HOLD
SW ITCH
T HERMOSTAT
SHUT-OF F
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUN TING
PLATE
MOTOR
NEUT RAL
BLK
BLK
B LK
BLK
BLU
LT. BLU
LT. BLU
BRN
RED
GRN / yEL
GRN / yEL
REd
YEL
YEL
YEL
P-3
P-1
P-2
P-4