background image

4

   

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Grounding type wall
receptacle

Do not, under any cir-
cumstances, cut, re-
move, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Read all instructions before using this air conditioner.

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen. This information

can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.

• If the air conditioner is to be installed in a window, you will probably want to clean both

sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation.

• Be sure the air conditioner has been securely and correctly installed according to the

separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.

• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front

and rear coils.

Electrical Information

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,

proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall

receptacle you intend to use is not adequately grounded or protected by a time delay
fuse or circuit breaker, have a qualified electrician install the proper receptacle.

• Do not run air conditioner with outside protective cover in place. This could result in

mechanical damage within the air conditioner.

• Do not use an extension cord or an adapter plug.

Important Safety
Instructions

The power supply cord with

this air conditioner contains a current de-
tection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired it must be
replaced with a cord from the Product Manu-
facturer.

Operation of Current
Device

The  power supply cord contains a current device that senses damage to the power cord. To
test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button.

You will notice a click as the RESET button pops out.

3. Press the RESET button. Again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is

also indicated by a light on the plug head).

NOTES:

• Do not use this device to turn the unit on or off.
• Always make sure the RESET button is pushed in for correct operation.
• The power supply cord must be replaced if it fails to reset when either the TEST button is

pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.

• If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one

obtained from the product manufacturer.

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Plug in & 

press RESET

SZ000710(En)-JiXie

2005.9.13, 11:04 AM

4

Содержание 220201d053

Страница 1: ...1 USE CARE MANUAL ROTARY CONTROL AIR CONDITIONER P N 220201d053 READ AND SAVE THESE INSTRUCTIONS SZ000710 En JiXie 2005 9 13 11 04 AM 1 ...

Страница 2: ...s repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation This warranty does not cover the following 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EX...

Страница 3: ...Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal operation...

Страница 4: ...g is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with ou...

Страница 5: ...is manual are representative of many available models Your model may offer slightly different features Please always wait 3 minutes when turning unit off then on again and when changing from cool to fan back to cool This prevents compressor from overheating possible circuit breaker tripping SZ000710 En JiXie 2005 9 13 11 04 AM 5 Cool Mode The desired cool setting is selected by rotating the knob t...

Страница 6: ... may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Energy Saving Ideas Do not block air flow inside with blinds curtains or furniture or outside with shrubs ...

Страница 7: ...away from coil Outdoor temperature below 60 F 16 C To defrost the coil set selector to FAN position Then set thermostat to warmer position Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set selector to FAN Thermostat set too cold for night time cooling To defrost the coil set selector to a FAN position Then set thermostat to a warmer position Dirty air filter ai...

Отзывы: