background image

 
 
 
 

 
 

 

 

INSTALLATION & OWNER’S 
MANUAL 

 

Fancoil Unit of Duct Type

 

 

 

 

 

 

MKT3-V200   (KFC-PD-2T-200D) 
MKT3-V300   (KFC-PD-2T-300D) 
MKT3-V400   (KFC-PD-2T-400D) 
MKT3-V600   (KFC-PD-2T-600D) 
MKT3-V800   (KFC-PD-2T-800D) 
MKT3-V1000   (KFC-PD-2T-1000D) 
MKT3-V1200   (KFC-PD-2T-1200D) 
MKT3-V200F   (KFC-PD-4T-200D) 
MKT3-V300F   (KFC-PD-4T-300D) 
MKT3-V500F   (KFC-PD-4T-500D) 
MKT3-V600F   (KFC-PD-4T-600D) 
MKT3-V800F   (KFC-PD-4T-800D) 

 

 
 
 
 
 

 

 

 

 

 

Thank you very much for purchasing our air conditioner. Before using your air 

conditioner, please read this manual carefully and keep it for future reference.

 

Содержание KFC-PD-2T-1000D

Страница 1: ...V800 KFC PD 2T 800D MKT3 V1000 KFC PD 2T 1000D MKT3 V1200 KFC PD 2T 1200D MKT3 V200F KFC PD 4T 200D MKT3 V300F KFC PD 4T 300D MKT3 V500F KFC PD 4T 500D MKT3 V600F KFC PD 4T 600D MKT3 V800F KFC PD 4T 8...

Страница 2: ...des right and left whit these references MKT3 V200 KFC PD 2T 200D RIGHT MKT3 V400 KFC PD 2T 400D RIGHT MKT3 V200F KFC PD 4T 200D RIGHT MKT3 V300F KFC PD 4T 300D RIGHT MKT3 V500F KFC PD 4T 500D RIGHT M...

Страница 3: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Страница 4: ...horough check Regret for no further announcement if there is any change of this manual caused by product improvement 3 FUNCTIONS FEATURES Nested in the ceiling space saving and noble High capacity of...

Страница 5: ...unit where connotative heat is emitted from a heat source directly CAUTION Scope of dismantling the ceiling Please keep the ceiling horizontal Reinforce the beams and girders of the ceiling lest vibra...

Страница 6: ...ally Lack of horizontality may cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire co...

Страница 7: ...585 685 905 841 941 1161 683 783 1003 1233 1338 1205 1310 1461 1566 1303 1408 1628 1600 1856 1698 1794 1766 2022 1864 NOTE The above figures is an instance models which would be different from the on...

Страница 8: ...es are smooth and the adapters are sealed Newly built rooms should undergo the drain test before the ceiling is laid NOTE Be sure to perform heat insulation for the drainpipe of the indoor unit Otherw...

Страница 9: ...n fixed wiring The appliance shall be installed in accordance with national wiring regulations Be sure to locate the power wiring and the signal wring well to avoid cross disturbance Do not turn on th...

Страница 10: ...UE YELLOW RED HI SPEED MI SPEED LO SPEED 10 1 Wiring Diagram ON ON S8S 7 S6 OF F S5 S4 OF F LED 4 SW1 SW2 CN3 MAIN BOAD ALARM EARTH CN1 CN2 CN5 CN8 MOTOR1 MOTOR2 L N HI MID LOW N POWER IN YELLOW GREEN...

Страница 11: ...300CFM 51WA single m otor 400CFM 68WA single m otor 500CFM 85WA single m otor 600CFM 102WA single m otor 800CFM 136WA double m otor 1000CFM 170WA double m otor 1200CFM 204WA double m otor Not set mode...

Страница 12: ......

Отзывы: