Power Supply 

9-24V DC 

Power Consumption 

Up to 10W 

Operating Temperature 

-20°C to 75°C (4°F to 167°F) 

Storage Temperature 

-40°C to 85°C (-40°F to 185°F) 

Enclosure 

Plastic   

Fixedness 

Mounting ear with screws 

Humidity 

20 - 80% RH [Not Condensation] 

Device Dimension 

68x88x27 mm (WxDxH) 

Package Dimension 

160x130x38 mm (WxDxH) 

 

Default System Settings 

Please connect your PC to GW-3201M via LAN port. The default IP address of 

LAN

 is 

192.168.100.1

. The 

account and password for Friendtrol Installation Wizard is listed as below. 

 
Installation Wizard: 

  admin / admin 
 

 

 

 

 

 

Содержание GW-3201M1

Страница 1: ...User Manual GW 3201M1 Serial to IP Intelligent Gateway with Modbus conversion Rev Oct 2019 Made in Taiwan...

Страница 2: ...tificated for use s The purpose of limits is to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment Before you attempt to unpack or us...

Страница 3: ...nt Gateway with Modbus conversion The major purpose of this device is to convert Modus UTP to Modbus TCP either way CTR 3201M1 provides one IP port and two Serial ports for conversion The two serial p...

Страница 4: ...GW 3201M1 Manual Rear Panel Top Panel 4 4 5 7 8 9 10 11 6...

Страница 5: ...X of Serial Port 2 9 Green LED TX of Serial Port 1 10 Red LED RX of Serial Port 1 11 Yellow LED System indication Specification I O Interface Ethernet 1 x RJ 45 Connector 10 100 Mbps ICMP TCP IP DHCP...

Страница 6: ...Plastic Fixedness Mounting ear with screws Humidity 20 80 RH Not Condensation Device Dimension 68x88x27 mm WxDxH Package Dimension 160x130x38 mm WxDxH Default System Settings Please connect your PC to...

Страница 7: ...ser to set up this gateway quickly User just needs to follow the three steps below and will complete the configuration in a short time 1 Network The first step is to set up Ethernet port for general I...

Страница 8: ...re there is no attack from uncertain IP address white list is built for this case Therefore only the IP address in the white list can access GW 3201M1 1 3 VPN When the user wants GW 3201M1 can access...

Страница 9: ...Network Status User can see the Network status in this section 2 Serial Setup The second step is to set up the general settings 9 User can see the Network status in this section general settings for...

Страница 10: ...10 3 Gateway Setup This third step is to complete the conversion between Modbus RTU and Modbus TCP Bi directional 4 System This section is to see the log and the status of the whole System and even s...

Отзывы: